Description
The PROVA-6605 Power & Harmonics Tester is a high-precision instrument designed for comprehensive AC power measurement and harmonic analysis. It supports single-phase and three-phase systems, measuring active (W, KW, HP), reactive (VAR, KVAR), and apparent power (VA, KVA), as well as energy (WH, KWH), power factor, and phase angle.
With True RMS measurement and fast peak detection (39 μs for 50 Hz, 33 μs for 60 Hz), it accurately captures voltage and current even under non-linear load conditions. The device performs non-interrupted harmonic analysis from 1st to 99th order, with a basic accuracy of 2% for harmonics. It calculates total harmonic distortion (%THD-F) and monitors the crest factor (CF) for both voltage and current.
The PROVA-6605 includes resistance and continuity testing with audible alerts, supports 1 to 250 programmable CT ratios, and provides functions for Max, Min, and Data Hold. It is portable, battery-operated, and features a 30-minute auto power-off, making it ideal for field and laboratory use.
Specifications
General Specifications:
| Conductor Size: |
55mm (approx.), 64 x 24mm (bus bar) |
| Battery Type: |
two 1.5V SUM-3 |
| Display: |
4+4 digits LCD |
| Range Selection: |
Auto |
| Overload Indication: |
OL |
| Power Consumption: |
10 mA(approx.) |
| Low battery Indication: |
|
| Auto-Power-Off: |
30 minutes after power-on |
| Update Time: |
2 times/second (display) |
| No. Of Samples per Period |
512 (voltage or current)
256 (power) |
| Operating Temperature: |
-10°C to 50°C |
| Operating Humidity: |
less than 85% relative |
| Altitude: |
up to 2000M |
| Storage Temperature: |
-20°C to 60°C |
| Storage Humidity: |
less than 75% relative |
| Dimension: |
271mm (L) x 112mm (W) x 46mm (H)
10.7″ (L) x 4.4″ (W) x 1.8″ (H) |
| Weight: |
647g / 22.8 oz (battery included) |
| Accessories: |
test leads x 1 pair
Carrying bag x 1
Users manual x 1
Batteries 1.5V x 2 |
| Option: |
Alligator clips |
Electrical Specifications: (23℃±5℃)
AC Watt (Range: 0~1500A)
| Range |
Resolution |
Accuracy of Readings |
| > 20 V and > 20A |
< 20V or < 20A |
| 10.0 – 999.9 W |
0.1W |
±1% ± 20dgts |
±2% ± 40dgts |
| 1.000 – 9.999 KW |
0.001 KW |
±1% ±20dgts |
±2% ±40dgts |
| 10.00 – 99.99 KW |
0.01 KW |
±1% ±20dgts |
±2% ±40dgts |
| 100.0 – 999.9 KW |
0.1 KW |
±1% ±20dgts |
±2% ±40dgts |
| 1000 – 9999 KW |
1 KW |
±1% ±20dgts |
±2% ±40dgts |
AC Apparent Power (Range: 0~1500A)
| Range |
Resolution |
Accuracy of Readings |
| > 20 V & > 20A |
< 20V or < 20A |
| 10.0 – 999.9 VA |
0.1VA |
±1% ±20dgts |
±2% ±40dgts |
| 1.000 – 9.999 KVA |
0.001 KVA |
±1% ±20dgts |
±2% ±40dgts |
| 10.00 – 99.99 KVA |
0.01 KVA |
±1% ±20dgts |
±2% ±40dgts |
| 100.0 – 999.9 KVA |
0.1 KVA |
±1% ±20dgts |
±2% ±40dgts |
| 1000 – 9999 KVA |
1 KVA |
±1% ±20dgts |
±2% ±40dgts |
AC Reactive Power (Range: 0~1500A)
| Range |
Resolution |
Accuracy of Readings |
| > 20 V & > 20A |
< 20V or < 20A |
| 10.0 – 999.9 VAR |
0.1VAR |
±2% ±30dgts |
±3% ±40dgts |
| 1.000 – 9.999 KVAR |
0.001 KVAR |
±2% ±30dgts |
±3% ±40dgts |
| 10.00 – 99.99 KVAR |
0.01 KVAR |
±2% ±30dgts |
±3% ±40dgts |
| 100.0 – 999.9 KVAR |
0.1 KVAR |
±2% ±30dgts |
±3% ±40dgts |
| 1000 – 9999 KVAR |
1 KVAR |
±2% ±30dgts |
±3% ±40dgts |
AC Current (50/60Hz, AutoRange, TRMS, C,F,<4, CT=1, OL Protection AC 2000A)
| Range |
Resolution |
Accuracy of Readings |
| 4.0 – 1500.0 A (for PROVA 6605) |
0.1 A |
±1.0% ± 5dgts |
AC Voltage
(50/60Hz, AutoRange, TRMS, C.F.<4, Input Impedance 10 MΩ, Overload Protection AC 800V)
| Range |
Resolution |
Accuracy of Readings |
| 4.0 V – 600.0 V |
0.1 V |
±0.5% ± 5dgts |
Harmonics of AC Voltage in Percentage
| Range |
Resolution |
Accuracy |
| 1 – 20th |
0.1% |
±2% |
| 21 – 49th |
0.1% |
4% of reading ±2.0% |
| 50 – 99th |
0.1% |
6% of reading ±2.0% |
Harmonics of AC Voltage in Magnitude
| Range |
Resolution |
Accuracy |
| 1 – 20th |
0.1% |
2% of reading ± 0.5V |
| 21 – 49th |
0.1% |
4% of reading ±0.5V |
| 50 – 99th |
0.1% |
6% of reading ±0.5V |
Harmonics of AC Current in Percentage
| Range |
Resolution |
Accuracy |
| 1 – 20th |
0.1% |
±2% |
| 21 – 49th |
0.1% |
4% of reading ±2.0% |
| 50 – 99th |
0.1% |
6% of reading ±2.0% |
Harmonics of AC Current in Magnitude
| Range |
Resolution |
Accuracy |
| 1 – 20th |
0.1% |
±2% of reading ±0.4A |
| 21 – 49th |
0.1% |
±4% of reading ±0.4A |
| 50 – 99th |
0.1% |
±6% of reading ±0.4A |
Power Factor (PF)
| Range |
Resolution |
Accuracy |
| > 20V and > 20A |
< 20V or < 20A |
| 0.000 – 1.000 |
0.001 |
± 0.04 |
±0.1 |
Phase Angle (Φ, > 20V and > 20A)
| Range |
Resolution |
Accuracy |
| -180° to 180° |
0.1° |
± 1.5° |
| 0° to 360° |
0.1° |
± 1.5° |
Total Harmonic Distortion
| Range |
Resolution |
Accuracy |
| 0.0 – 20% |
0.1% |
± 2% |
| 20.1 – 100% |
0.1% |
± 6% of reading ± 1% |
| 100.1 – 999.9 % |
0.1% |
± 10% of reading ± 1% |
Peak Value of AC Voltage (peak value > 5V) or AC Current (peak value > 20A)
| Range |
Sampling Time |
Accuracy of Reading |
| 50 Hz |
39 μs |
± 5% ± 30 digits |
| 60 Hz |
33 μs |
± 5% ± 30 digits |
Resistance (Ω) and Continuity (Beep if less than 50Ω)
| Range |
Resolution |
Accuracy |
| 7.0 – 999.9 Ω |
0.1Ω |
± 5Ω |
| 1000-1200Ω |
1Ω |
± 5Ω |
Crest Factor (C.F.)of ACV (peak value > 5V) or ACA (peak value > 20A)
| Range |
Resolution |
Accuracy of Readings |
| 1.00 – 99.99 |
0.01 |
± 5% ± 30 digits |
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
| Range |
Resolution |
Accuracy |
| 45 – 65 |
0.1 |
± 0.2Hz |