Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES TES-3910 Trms Clamp Meter (DC/AC 1000A)

The TES-3910 Trms Clamp Meter measures AC/DC current up to 1000A with True RMS accuracy, featuring inrush current measurement, capacitance, Lo-Z voltage detection, and 3Φ phase sequence indication. Ideal for HVAC, electrical, and industrial applications.

  • True RMS AC/DC Measurement up to 1000A
  • Capacitance Measurement up to 1000µF
  • Lo-Z Voltage Measurement to eliminate ghost voltages
  • 3Φ Phase Sequence Check for motor and electrical systems

Description

The TES-3910 Trms Clamp Meter is a versatile, high-precision tool designed for professional electricians, HVAC technicians, and industrial maintenance personnel. It offers True RMS readings for AC and DC currents up to 1000A, ensuring accurate measurements even in circuits with distorted waveforms. Its Lo-Z voltage mode effectively removes ghost voltages, allowing safe and reliable testing.

This meter is capable of measuring capacitance up to 1000µF, inrush current, and variable-frequency drive (VFD) voltage and frequency, making it ideal for complex electrical systems. Additionally, it can verify 3-phase motor wiring using its phase sequence detection. The TES-3910 also provides diode and resistance testing, along with a data hold and peak hold mode for convenient on-site readings.

Its ergonomic design supports a maximum conductor diameter of 33 mm, and it comes with a full set of accessories, including test leads, a carrying case, and batteries. With data memory and read functions, the TES-3910 allows technicians to log measurements for later analysis, enhancing productivity and safety in the field.

Features

  • Capacitance Measurement: 1µF to 1000µF

  • AC/DC Current: Up to 1000A with True RMS accuracy

  • Inrush Current Measurement: Ideal for motor startup analysis

  • Lo-Z Voltage Measurement: Eliminates ghost voltages

  • 3Φ Phase Sequence Indication: Check motor and system wiring

  • VFD Voltage & Frequency: Measure variable frequency drives

  • Diode & Continuity Testing with audible beeper

  • Data Hold, Auto Hold, Peak Hold for convenience

  • Max/Min/Avg Record Mode for logging electrical data

  • Data Memory & Read Function for analysis

  • Compact Design: Ø33 mm conductor max, portable for fieldwork

  • Safety Category: CAT III 1000V / CAT IV 600V

Specifications

GENERAL SPECIFICATION:

Parameter Specification
Safety Category CAT III 1000 V
CAT IV 600 V
Maximum Conductor / Wire Diameter 33 mm
Dimensions (L × W × T) 236 × 80 × 39 mm
Weight 332 g (including battery)
Included Accessories • Instruction Manual × 1
• Battery × 1
• Carrying case × 1
• Test leads × 1 pair

 

ELECTRICAL SPECIFICATIONS (23℃±5℃)

AC Current (40Hz to 400Hz) : VFD Trms

Range Resolution Accuracy Sensitivity Overload Protection
99.99A 10mA ±2%±20dgts (50, 60Hz) ±4%±20dgts (40~400Hz) >0.25A 1000A AC
999.9A 100mA >2.5A

 

DC Current :

Range Resolution Accuracy Sensitivity Overload Protection
99.99A 10mA ±2% ±20dgts >0.25A 1000A
999.9A 100mA >2.5A

 

ACA Inrush Current : VFD Trms

Range Resolution Sensitivity Measurement Time Overload Protection
99.99A 0.01A >5A 100mS 1000AAC

 

DCμA : (Burden Voltage : 3.6mV/µA)

Range Resolution Accuracy Sensitivity Overload Protection
99.99μA 10nA ±1% ±20dgts >0.30µA 1000V
999.9μA 100nA >3.0µA

 

ACmA : VFD Trms (Burden Voltage : 3.6mV/µA)

Range Resolution Accuracy Sensitivity Overload Protection
99.99mA 10nA ±1%±10dgts (50, 60Hz) ±2%±10dgts (40~400Hz) >0.30µA 1000V
999.9mA 100nA >3.0µA

 

AC Voltage (40Hz to 400Hz) : VFD Trms

Range Resolution Accuracy Sensitivity Overload Protection
999.9mV 0.1mV ±1%±10dgts (50, 60Hz) ±2%±10dgts (40~400Hz) 40 ~ 300Hz on mV range >2mV 1000V (LoZ: 600V 1 minute)
9.999V 1mV >20mV
99.99V 10mV >200mV
999.9V   100mV >2V

 

DC Voltage

Range Resolution Accuracy Sensitivity Overload Protection
999.9mV 0.1mV ±1% ±10dgts >2mV 1000V (LoZ: 600V 1 minute)
9.999V 1mV >20mV
99.99V 10mV >200mV
999.9V   100mV >2V

 

Resistance (Continuity<40Ω on the range) :

Range Resolution Accuracy Overload Protection
999.9Ω 100mΩ ±1% ±10dgts 1000V
9.999KΩ 1Ω
99.99KΩ 10Ω
999.9KΩ 100Ω

 

3Φ Phase sequence indication :

Range Frequency Response Overload Protection
80V to 480V 50Hz / 60Hz 1000V

 

Diode (Continuity<40mV) :

Range Resolution Accuracy Overload Protection
3.000V 1mV ±1% ±10dgt 1000V

 

Frequency :

Range Resolution Accuracy Sensitivity
40Hz/1KHz 0.1Hz ±0.5%rdg ±2dgts        V > 5% range          μA, A > 30%

 

Capacitance:

Range Resolution Accuracy Overload Protection
1.000μF 1nF ±1.5%±5dgts 1000V
10.00μF 10nF
100.0μF 100nF
1000μF F

 

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.