TES TES-3040H Digital AC Clamp Meter

The TES-3040H Digital AC Clamp Meter measures AC/DC current, voltage, resistance, and frequency accurately. It features auto-ranging, MAX/MIN hold, data hold, and a bar-graph display for fast readings.

  • Display: 3-3/4 digit LCD with bar-graph, max reading 3999
  • Auto Ranging: Voltage, current, resistance, and frequency
  • AC Current: Up to 1000A TRMS, low-pass filter
  • AC/DC Voltage: Up to 600V

Description

The TES-3040H Digital AC Clamp Meter provides precise measurements for electricians, technicians, and engineers. Its LCD with bar-graph shows AC/DC voltage, current, resistance, frequency, and diode readings clearly. Auto-ranging and low-pass filtering deliver accurate TRMS measurements, even in complex circuits. The meter supports MAX/MIN hold, data hold, and zero adjustment, helping users capture transient signals and perform relative measurements efficiently.

This meter ensures safety and convenience. It alerts users for overrange conditions and low battery. The audible continuity checker and diode test simplify troubleshooting. The meter weighs only 430g, runs on a standard 9V battery, and automatically powers off after 30 minutes to save energy. Its compact design makes it easy to carry for field or workshop use.

Features

  • 3-3/4 Digit LCD with bar-graph, max reading 3999

  • Auto Ranging for AC/DC voltage, current, resistance, and frequency

  • AC Current: TRMS up to 1000A, low-pass filter

  • AC/DC Voltage: Up to 600V with autorange

  • Resistance & Continuity Beeper: Up to 40Ω

  • Diode Test: Open circuit voltage 3.2V, short-circuit current 1mA

  • Frequency Measurement: Voltage and current, autorange

  • Data Hold & MAX/MIN Hold: Captures transient signals

  • Zero Adjustment / Relative Reading for precise comparison

  • Auto-Power-Off: ~30 minutes to save battery

  • Lightweight & Portable: 430 g with battery

  • Included Accessories: Test leads, 9V battery, carrying case, instruction manual

Specifications

GENERAL SPECIFICATION:

Parameter Specification
Display 3-3/4 digit LCD, maximum reading 3999
Range Selection All ranges selected by a single rotary range switch
Over Range Indication LCD shows flashing “OL” in the highest position + continuous beeping
(except for 1000 A AC and 600 V DC / 600 V AC ranges)
Low Battery Indication Battery symbol ( ) appears when voltage drops below operating level
Sampling Rate 20 times/sec (Bar graph)
2 times/sec (Digital display)
Power Source 1 × 006P 9 V battery (equivalent to IEC 6F22 or NEDA 1604)
Battery Life Approx. 100 hours (with alkaline battery)
Polarity Indication Automatic ” – ” display for negative input
Auto Power Off Approx. 30 minutes
Operating Temperature & Humidity 0°C to 50°C (32°F to 122°F), below 80% RH (non-condensing)
Storage Temperature & Humidity -10°C to 60°C (14°F to 140°F), below 70% RH (non-condensing)
Dimensions (L × W × H) 239 × 66 × 34 mm
Weight Approx. 430 g (including battery)
Included Accessories • Instruction manual × 1
• 9 V battery × 1
• Test leads × 1 pair
• Carrying case × 1

 

 MEASUREMENT SPECIFICATIONS:

 AC Current (Autorange & Manual): Low Pass Filter
Range
Resolution
Accuracy
Overload protection
Frequency
Response
400A
0.1A
±(2% + 10)
1100A
40~450 Hz
1000A
1A
 Conversion type: AC coupled, TRMS measurement.
 Additional Crest Factor Errors (non – sinecure)
Crest Factor
Error (% of reading)
1 – 3
0.5%
3 – 5
3%
5 – 7
6%
 Response time: 5 seconds max, to rated accuracy within selected range.

INFLUENCE OUANTITY

Influence quantity
Limits of variation
Measured quantity
Tolerance
Position of conductor in the clamp conductor’s diameter: 20mm
In relation to the center
Amps
±(1%+5)
DC Voltage (Autorange & Manual)
Range
Resolution
Accuracy
Input Impedance
Overload protection
400mV
0.1mV
±(0.75% + 2)
≒ 11MΩ
600Vrms
4V
0.001V
≒ 10MΩ
40V
0.01V
400V
0.1V
600V
1V
 Response time: 3 seconds max. to rated accuracy within selected range.
 AC Voltage (Autorange & Manual): Low Pass Filter
Range
Resolution
Accuracy
Input impedance
Overload protection
Frequency
Response
4V
0.001V
±(1.2%+5)
≒ 11MΩ
600Vrms
40~450 Hz
40V
0.01V
≒ 10MΩ
400V
0.1V
600V
1V
±(1.5%+5)
 Conversion type: AC coupled, TRMS measurement.
Additional Crest Factor Errors (non – sinecure)
Crest Factor
Error (% of reading)
1 – 3
0.5%
3 – 5
3%
5 – 7
6%
 Response time: 5 seconds max, to rated accuracy within selected range.
 Frequency (Hz) (Autorange for Voltage)
Range
Resolution
Accuracy
Sensitivity
Overload protection
100Hz
0.01Hz
±(0.1% + 2)
100mV
600Vrms
1KHz
0.1Hz
5KHz
0.001KHz
Frequency (Hz) (Autorange for Current)
Range
Resolution
Accuracy
Sensitivity
Overload protection
100Hz
0.01Hz
±(0.5% + 5)
5A
1100A
1KHz
0.1Hz
Resistance (Ω) (Autorange & Manual)
Range
Resolution
Accuracy
Open circuit
Voltage
Overload protection
400Ω
0.1Ω
±(1% + 5)
≦ 0.5 VDC
600Vrms
4KΩ
0.001KΩ
±(1% + 3)
40KΩ
0.01KΩ
400KΩ
0.1KΩ
4MΩ
0.001MΩ
40MΩ
0.01MΩ
±(1.5% + 3)
Audible continuity
Range
Continuity beeper
Open Circuit Voltage
Overload  protection
≦ 40Ω
≦ 0.5V
600Vrms
 Diode test
Range
Resolution
Accuracy
Overload protection
         
0.001V
±(1%+2)
600Vrms
 Max. open circuit Voltage: 3.2V
 Max. short circuit Current: 1.0mA (typical).