Description
The TES-3040H Digital AC Clamp Meter provides precise measurements for electricians, technicians, and engineers. Its LCD with bar-graph shows AC/DC voltage, current, resistance, frequency, and diode readings clearly. Auto-ranging and low-pass filtering deliver accurate TRMS measurements, even in complex circuits. The meter supports MAX/MIN hold, data hold, and zero adjustment, helping users capture transient signals and perform relative measurements efficiently.
This meter ensures safety and convenience. It alerts users for overrange conditions and low battery. The audible continuity checker and diode test simplify troubleshooting. The meter weighs only 430g, runs on a standard 9V battery, and automatically powers off after 30 minutes to save energy. Its compact design makes it easy to carry for field or workshop use.
Specifications
GENERAL SPECIFICATION:
| Parameter |
Specification |
| Display |
3-3/4 digit LCD, maximum reading 3999 |
| Range Selection |
All ranges selected by a single rotary range switch |
| Over Range Indication |
LCD shows flashing “OL” in the highest position + continuous beeping
(except for 1000 A AC and 600 V DC / 600 V AC ranges) |
| Low Battery Indication |
Battery symbol ( ) appears when voltage drops below operating level |
| Sampling Rate |
20 times/sec (Bar graph)
2 times/sec (Digital display) |
| Power Source |
1 × 006P 9 V battery (equivalent to IEC 6F22 or NEDA 1604) |
| Battery Life |
Approx. 100 hours (with alkaline battery) |
| Polarity Indication |
Automatic ” – ” display for negative input |
| Auto Power Off |
Approx. 30 minutes |
| Operating Temperature & Humidity |
0°C to 50°C (32°F to 122°F), below 80% RH (non-condensing) |
| Storage Temperature & Humidity |
-10°C to 60°C (14°F to 140°F), below 70% RH (non-condensing) |
| Dimensions (L × W × H) |
239 × 66 × 34 mm |
| Weight |
Approx. 430 g (including battery) |
| Included Accessories |
• Instruction manual × 1
• 9 V battery × 1
• Test leads × 1 pair
• Carrying case × 1 |
MEASUREMENT SPECIFICATIONS:
AC Current (Autorange & Manual): Low Pass Filter
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
Frequency
Response
|
|
400A
|
0.1A
|
±(2% + 10)
|
1100A
|
40~450 Hz
|
|
1000A
|
1A
|
Conversion type: AC coupled, TRMS measurement.
Additional Crest Factor Errors (non – sinecure)
|
Crest Factor
|
Error (% of reading)
|
|
1 – 3
|
0.5%
|
|
3 – 5
|
3%
|
|
5 – 7
|
6%
|
Response time: 5 seconds max, to rated accuracy within selected range.
INFLUENCE OUANTITY
|
Influence quantity
|
Limits of variation
|
Measured quantity
|
Tolerance
|
|
Position of conductor in the clamp conductor’s diameter: 20mm
|
In relation to the center
|
Amps
|
±(1%+5)
|
DC Voltage (Autorange & Manual)
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload protection
|
|
400mV
|
0.1mV
|
±(0.75% + 2)
|
≒ 11MΩ
|
600Vrms
|
|
4V
|
0.001V
|
≒ 10MΩ
|
|
40V
|
0.01V
|
|
400V
|
0.1V
|
|
600V
|
1V
|
Response time: 3 seconds max. to rated accuracy within selected range.
AC Voltage (Autorange & Manual): Low Pass Filter
|
Range
|
Resolution
|
Accuracy
|
Input impedance
|
Overload protection
|
Frequency
Response
|
|
4V
|
0.001V
|
±(1.2%+5)
|
≒ 11MΩ
|
600Vrms
|
40~450 Hz
|
|
40V
|
0.01V
|
≒ 10MΩ
|
|
400V
|
0.1V
|
|
600V
|
1V
|
±(1.5%+5)
|
Conversion type: AC coupled, TRMS measurement.
Additional Crest Factor Errors (non – sinecure)
|
Crest Factor
|
Error (% of reading)
|
|
1 – 3
|
0.5%
|
|
3 – 5
|
3%
|
|
5 – 7
|
6%
|
Response time: 5 seconds max, to rated accuracy within selected range.
Frequency (Hz) (Autorange for Voltage)
|
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload protection
|
|
100Hz
|
0.01Hz
|
±(0.1% + 2)
|
100mV
|
600Vrms
|
|
1KHz
|
0.1Hz
|
|
5KHz
|
0.001KHz
|
Frequency (Hz) (Autorange for Current)
|
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload protection
|
|
100Hz
|
0.01Hz
|
±(0.5% + 5)
|
5A
|
1100A
|
|
1KHz
|
0.1Hz
|
Resistance (Ω) (Autorange & Manual)
|
Range
|
Resolution
|
Accuracy
|
Open circuit
Voltage
|
Overload protection
|
|
400Ω
|
0.1Ω
|
±(1% + 5)
|
≦ 0.5 VDC
|
600Vrms
|
|
4KΩ
|
0.001KΩ
|
±(1% + 3)
|
|
40KΩ
|
0.01KΩ
|
|
400KΩ
|
0.1KΩ
|
|
4MΩ
|
0.001MΩ
|
|
40MΩ
|
0.01MΩ
|
±(1.5% + 3)
|
Audible continuity
|
Range
|
Continuity beeper
|
Open Circuit Voltage
|
Overload protection
|
|
|
≦ 40Ω
|
≦ 0.5V
|
600Vrms
|
Diode test
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
|
|
0.001V
|
±(1%+2)
|
600Vrms
|
Max. open circuit Voltage: 3.2V
Max. short circuit Current: 1.0mA (typical).