TES AFLEX-6300 Graphic Power Quality Analyzer
- Power Quality Analysis for Single and Balanced Three Phase System
- Harmonic Analysis of Voltage and Current (1 to 50th order)
- True RMS measurement of V with 0.5% basic accuracy
- True RMS measurement of A with 1% of range basic accuracy
- Graphic Waveform of Voltage and Current Graphic Phasor Diagram
- Transient Detection and Logging of Swell, Dip, and Outage
- Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
- Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power
- Power factor (PF), phase angle (Φ), and energy (WH, KWH)
- Measurement of balanced 3Φ Power Quality
- Programmable VT ratio from 1 to 3000 Hold functions
- Auto power off function in 15 minutes
Electrical Specifications: (23℃±5℃)
AC Watt
| Range | Resolution | Accuracy of Readings | |
| > 20 V and > 30A | < 20V or < 30A | ||
| 10.0 – 999.9 W | 0.1W | ±1% of Range ±0.3W | ±2% of Range |
| 1.000 – 9.999 KW | 0.001 KW | ±1% of Range ±0.003KW | ±2% of Range |
| 10.00 – 99.99 KW | 0.01 KW | ±1% of Range ±0.03KW | ±2% of Range |
| 100.0 – 999.9 KW | 0.1 KW | ±1% of Range ±0.3KW | ±2% of Range |
| 1000 – 9999 KW | 1 KW | ±1% of Range ±3KW | ±2% of Range |
AC Apparent Power (VA)
| Range | Resolution | Accuracy of Readings | |
| > 20 V and > 30A | <20V or < 30A | ||
| 10.0 – 999.9 VA | 0.1VA | ±1% of Range ±0.3VA | ±2% of Range |
| 1.000 – 9.999 KVA | 0.001 KVA | ±1% of Range ±0.003KVA | ±2% of Range |
| 10.00 – 99.99 KVA | 0.01 KVA | ±1% of Range ±0.03KVA | ±2% of Range |
| 100.0 – 999.9 KVA | 0.1 KVA | ±1% of Range ±0.3KVA | ±2% of Range |
| 1000 – 9999 KVA | 1 KVA | ±1% of Range ±3KVA | ±2% of Range |
AC Reactive Power (VAR)
| Range | Resolution | Accuracy of Readings | |
| > 20 V and > 30A | <20V or < 30A | ||
| 10.0–999.9 VAR | 0.1VAR | ±1% of Range ±0.3VAR | ±2% of Range |
| 1.000–9.999 KVAR | 0.001 KVAR | ±1% of Range ±0.003KVAR | ±2% of Range |
| 10.00–99.99 KVAR | 0.01 KVAR | ±1% of Range ±0.03KVAR | ±2% of Range |
| 100.0–999.9 KVAR | 0.1 KVAR | ±1% of Range ±0.3KVAR | ±2% of Range |
| 1000 – 9999 KVAR | 1 KVAR | ±1% of Range ±3KVAR | ±2% of Range |
Power Factor (PF)
| Range | Resolution | Accuracy | |
| > 20V & > 30A | < 20V or < 30A | ||
| 0.000 – 1.000 | 0.001 | ± 0.04 | ±0.1 |
AC Current
| Range | Resolution | Accuracy of Readings |
| 3A – 300.0A | 0.1A | ±1% of Range ±0.3A |
| 300.0 – 3000A | 0.1A / 1A | ±1% of Range ±3A |
AC Voltage (Overload Protection AC 800V)
| Range | Resolution | Accuracy of Readings |
| 4.0 V – 600.0 V | 0.1 V | ±0.5% ± 5dgts |
Harmonics of AC Voltage in Percentage
| Range | Resolution | Accuracy |
| 1 – 20th | 0.1% | ±2% |
| 21 – 50th | 0.1% | 4% of reading ±2.0% |
Harmonics of AC Voltage in Magnitude
| Range | Resolution | Accuracy |
| 1 – 20th | 0.1% | ±2% ± 0.5V |
| 21 – 50th | 0.1% | 4% of reading ±0.5V |
Harmonics of AC Current in Percentage
| Range | Resolution | Accuracy |
| 1 – 20th | 0.1% | ±2% |
| 21 – 50th | 0.1% | ±6% |
Harmonics of AC Current in Magnitude (True RMS < 300A)
| Range (0 – 300A) | Resolution | Accuracy |
| 1 – 20th | 0.1% | ±2% of range ±0.4A |
| 21 – 50th | 0.1% | ±4% of range ±0.4A |
Harmonics of AC Current in Magnitude (3000A >True RMS> 300A)
| Range | Resolution | Accuracy |
| 1 – 20th | 0.1% | ±2% of range ±40A |
| 21 – 50th | 0.1% | ±4% of range ±40A |
Phase Angle (Φ, V > 20V, A > 30A)
| Range | Resolution | Accuracy |
| -180° to 180° | 0.1° | ± 2° |
| 0° to 360° | 0.1° | ± 2° |
Total Harmonic Distortion
| Range | Resolution | Accuracy |
| 0.0 – 20% | 0.1% | ± 2% |
| 20 – 100% | 0.1% | ± 7% |
| 100 – 999.9 % | 0.1% | ± 11% |
Peak Value of AC Voltage (RMS value > 20V) or AC Current (RMS value > 30A)
| Range | Sampling Time | Accuracy of Reading |
| 50 Hz | 39 μs | ± 5% ± 50 digits |
| 60 Hz | 33 μs | ± 5% ± 50 digits |
Frequency of AC Voltage (RMS value > 20V) or AC Current (RMS value > 30A)
| Range | Resolution | Accuracy |
| 46 – 65 | 0.1 | ± 0.3Hz |
General Specifications:
| Probe Length: 6300-24 | 24 in / 610 mm |
| Minimum Bending Diameter: | 35mm |
| Connector Diameter: | 23mm |
| Cable Diameter: | 14mm |
| Cable Length from Probe to Box: | 1700mm |
| Cable Length from Box to Output: | 1700mm |
| Data Logging Memory Size: | 512K bytes |
| Maximum Transient Events: | 32000 |
| Dimension (Box): | 130 (L) x 80 (W) x 43 (H) mm
5.1” (L) x 3.1” (W) x 1.7” (H) |
| Battery Type: | two 1.5V SUM-3 |
| Display: | 128 X 64 Dot Matrix LCD with Backlight |
| Range Selection: | Auto |
| Overload Indication: | OL |
| Power Consumption: | 10mA (approx) |
| Auto-Power-Off: | 15 minutes after power-on |
| LCD Update Time: | 2 times/sec. |
| No. Of Samples per Period | 512 (voltage or current); 256 (power) |
| Operating Temperature: | -10°C to 85°C |
| Operating Humidity: | 15% to 85% RH |
| Altitude: | up to 2000M |
| Storage Temperature: | -20°C to 85°C |
| Storage Humidity: | 15% to 85% RH |
| Weight: | 430g (battery included) |
| Accessories: | Test leads (red/black) x 1 set Users manual x 1
Batteries 1.5V x 2 Carrying Case x 1 Software CD x 1 Software users manual x 1 USB to RS232 cable x 1 |