Description
Electrical Specifications: (23℃±5℃)
DC Current:
| Range | Resolution | Accuracy | Overload Protection |
| 40A | 10mA | ±1.0%±2dgts |
DC 400A |
| 400A (0-150A) | 100mA | ±1.0%±2dgts | |
| 400A (150-200A) | 100mA | ±2.2%±2dgts | |
| 400A (200-400A) | 100mA | ±4.0%±2dgts |
Frequency:(auto range)
| Range (Hz) | Resolution (Hz) | Accuracy | Sensitivity | Overload Protection |
| 1 – 100K | 0.001 – 100 | ±0.5%±2dgts | 0.3A | AC 500A |
AC Current: (True RMS, Crest Factor <= 4)
| Range | Resolution | Accuracy | Overload Protection | |
| 50/60 Hz | 40 – 1KHz | |||
| 4A (0-500mA) | 1mA | ±1.5%±7dgts | ±2.0%±7dgts | AC 400A |
| 4A (500mA-4A) | 1mA | ±1.5%±3dgts | ±2.0%±4dgts | |
| 40A | 10mA | ±1.5%±3dgts | ±2.0%±4dgts | |
| 100A (0-100A) | 100mA | ±1.5%±3dgts | ±2.0%±4dgts | AC 500A |
| 400A (100-200A) | 100mA | ±2.2%±3dgts | ±2.5%±4dgts | |
| 400A (200-400A) | 100mA | ±4.0%±3dgts | ±5.0%±4dgts | |
General Specifications:
| Conductor Size: | 23mm max. (approx.) |
| Dimension (Box): | 183 (L) x 61.3 (W) x 35.6 (H) mm
7.2″ (L) x 2.5″ (W) x 1.4″ (H) |
| Battery Type: | two 1.5V SUM-3 |
| Display: | 3 3/4 LCD with 40 seg. bargraph |
| Range Selection: | Manual |
| Overload Indication: | OL |
| Power Consumption: | 20 mA (approx.) |
| Low Battery Indication: | |
| Sampling Time: | 3 times/sec. (display)
30 times/sec. (bargraph) |
| Operating Temperature: | -10°C to 50°C |
| Operating Humidity: | less than 85% relative |
| Altitude: | up to 2000M |
| Storage Temperature: | -20°C to 60°C |
| Storage Humidity: | less than 75% relative |
| Weight: | 190g (battery included) |
| Accessories: | Carrying bag x 1
Users manual x 1 1.5V battery x 2 |