Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES PROVA-A11 mA AC/DC Clamp Meter

The PROVA-A11 AC/DC Clamp Meter measures current, voltage, resistance, capacitance, and temperature with high accuracy. It features TRMS AC measurement, peak value detection, and a large 25mm jaw for easy use.

  • Measures AC/DC current: 6A / 60A
  • Measures AC/DC voltage: 60V / 600V
  • High resolution: DC 1mA, AC 0.1mA
  • Supports TRMS AC current measurement

Description

The PROVA-A11 Clamp Meter is a versatile tool designed for electricians and technicians. It provides high-resolution measurements for DC (1mA) and AC (0.1mA) currents. It measures AC/DC current up to 60A, AC/DC voltage up to 600V, and supports TRMS AC current measurement. The meter can also measure resistance, continuity, capacitance, diode, and temperature using K-type thermocouples.

The meter features dual display modes, allowing users to view Hold + Average, Max + Min, or ΔMax + ΔMin. It supports voltage and current peak detection, with Auto and Manual range selection for accurate readings. The 25mm large jaw fits most conductors, and the Low Pass Filter (LPF) reduces interference from VFD equipment. Its auto-power-off function with backlight ensures convenience and safety. The 6000-count LCD shows readings clearly, making it ideal for work in crowded switch boxes or cable areas.

Features

  • AC/DC Current Measurement: 6A / 60A

  • AC/DC Voltage Measurement: 60V / 600V

  • TRMS AC Current

  • High Resolution: DC 1mA, AC 0.1mA

  • Resistance, Continuity, Capacitance, Diode, and Temperature

  • Peak Value Detection: Voltage/Current

  • Dual Display Modes: Hold + Ave, Max + Min, ΔMax + ΔMin

  • Auto/Manual Range Selection

  • One Touch Zero

  • Large 25mm Jaw

  • Auto-Power-Off: 30 minutes

  • Backlight Display

  • Low Pass Filter (LPF, 1KHz, -3dB)

  • 600V Overload Protection

  • Ideal for crowded switch box or cable areas

Specifications

General Specifications

Parameter Specification
Use Environment Indoor Use
Maximum Conductor Size Ø 25 mm (approx.)
Battery Type 2 × 1.5 V SUM-3 (equivalent to AA size)
Display 6000 counts
Range Selection Auto and Manual
Overload Indication OL
Low Battery Indication Yes
Power Consumption Approx. 17 mA
Sampling Rate 2 times/sec
Auto Power Off 30 minutes
Operating Temperature 0°C to +50°C
Operating Humidity Less than 85% RH (non-condensing)
Maximum Altitude Up to 2000 m
Storage Temperature -20°C to +60°C
Storage Humidity Less than 75% RH (non-condensing)
Dimensions (L × W × H) 191 × 66 × 36 mm
(7.5″ × 2.6″ × 1.45″)
Weight 250 g (including batteries)
Included Accessories • Carrying bag × 1
• User manual × 1
• 1.5 V batteries × 2
• Test leads × 1
• K-type thermocouple × 1
• Adapter (for capacitance and K-type thermocouple) × 1

Electrical Specifications: (23℃±5℃)

 DC Current

Range Resolution Accuracy Overload Protection
mA (0-6A) 1mA ±2.0%±3dgts DC 40A
0-30A  

10mA

±2.0%±3dgts  

DC 100A

30-40A ±2.5%±3dgts
40-60A ±4.0%±5dgts

 Range 60A Peak MAX ±100A  Accuracy + (±2%±50dgts)

 

AC Current (True RMS, Crest Factor 3)

Range Resolution Accuracy Overload

Protection

50/60 Hz 40 – 100Hz
600mA 0.1mA ±1.5%±5dgts ±2.0%±5dgts AC 40A
    50/60 Hz 40 – 1KHz  
6000mA 1mA ±2.5%±5dgts ±3.0%±5dgts AC 40A
0-30A 10mA ±2.0%±5dgts ±2.5%±5dgts AC 100A
30-60A 10mA ±4.0%±5dgts ±5.0%±5dgts AC 100A

 

 DC Voltage (Overload Protection AC 600V) 

Range Resolution Accuracy Input Impedance
60V 10 mV ±1.5%±3dgts 10MΩ
600V 100 mV

 DCV Peak MAX ±600V   Accuracy + (±2%±50dgts) 

 

AC Voltage (True RMS, Input Impedance 10 MΩ) 

Range Resolution Accuracy Overload Protection
50/60 Hz 40 – 1KHz
60V 10mV ±1.5%±5dgts ±2.0%±5dgts AC 600V
600V 100mV

 ACV Peak MAX ±850V   Accuracy + (±2%±50dgts)

 

 Continuity (Open voltage 0.4V, Overload protection AC 600V)

Range Resolution Accuracy Beeping
600Ω 0.1Ω ±1.0%±2dgts <30.0Ω (approx.)

 

 Resistance (Ω(Open voltage 0.4V)

Range Resolution Accuracy Overload Protection
600Ω 0.1Ω  

±1.5%±2dgts

 

AC 600V

6KΩ 1Ω
60KΩ 10Ω
600KΩ 100Ω

 Temperature (for using K-Type thermocouples,  or ) 

Range Resolution Accuracy Overload Protection
-40 – 0  0.1  ±2.0%±2   

AC 300V

 

0 – 400  ±0.5%±2 
-40 – 32  0.1  ±2%±3.6 
32 – 752  ±0.5%±3.6

 Capacitance 

Range Resolution Accuracy Overload Protection
600nF 0.1nF ±2.0%±0.2 nF  

 

AC 600V

6μF 1nF ±2.0%±0.02μF
60μF 10nF ±2.0%±0.02μF
600μF 100nF ±2.0%±0.2μF
6000μF 1μF ±2.5%±5μF

 Diode Test 

Range Resolution Accuracy Overload Protection
0 – 1.999V 0.001V ±2.5%±5dgts AC 600V

 

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.