Description
The TES-3013 / TES-3014 Digital Clamp Meter is engineered for precise electrical measurement in industrial, commercial, and maintenance environments. It combines high-resolution AC/DC current measurement with full voltage, resistance, continuity, and capacitance functions. The meter features a large LCD, easy-to-use rotary switch, and fast sampling for accurate readings. Peak and data hold functions ensure transient currents and voltages are captured reliably.
Designed for versatility, the TES-3013 / TES-3014 supports variable-frequency drive (VFD) measurement, making it ideal for motor and automation systems. Safety is ensured with CAT II 1000V and CAT III 600V protection, while its compact, lightweight design with included accessories ensures portability for fieldwork. This meter is suitable for electricians, technicians, and engineers requiring reliable, high-performance measurement in challenging environments.
Specifications
General Specification:
| Parameter |
Specification |
| Operating Temperature & Humidity |
0°C to 40°C, 0–80% RH (non-condensing) |
| Sampling Rate |
2.5 times per second |
| Peak Value Response Time |
Approximately 100 ms |
| Power Source |
006P DC 9 V battery × 1 pc (standard 9V block battery) |
| Dimensions (L × W × H) |
208 × 65 × 31 mm |
| Weight |
310 g (including battery) |
| Included Accessories |
• Test probe × 1 pair
• Instruction Manual × 1
• Carrying Case × 1
• 9 V battery × 1 |
ELECTRICAL SPECIFICATION:
AC Current
|
Range
|
Resolution
|
Accuracy (50Hz/60Hz)
|
Overload Protection
|
|
20A
|
10mA
|
±(2%rdg + 5dgts)
|
1000A(Within 30 seconds)
|
|
200A
|
100mA
|
|
600A. 1000A
|
1A
|
DC Voltage
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload Protection
|
|
600V
|
1V
|
±(0.8%rdg + 2dgt)
|
10MΩ
|
600V
|
AC Voltage
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload Protection
|
|
600V
|
1V
|
±(1.2%rdg + 3dgts) at 50, 60Hz
±(5%rdg + 3dgts) at 40 ~ 400Hz
|
10MΩ
|
600V
|
Resistance (Ω)
|
Range
|
Resolution
|
Accuracy
|
Max. Open Circuit Voltage
|
Overload Protection
|
|
200Ω
|
100mΩ
|
±(1%rdg + 2dgts)
|
3.5V
|
600V
|
|
20kΩ
|
10Ω
|
0.3V
|
Frequency (Hz) (10Hz-2KHz)
|
Range
|
Resolution
|
Accuracy
|
Max. Input Sensitivity
|
Max. Allowable Applied Voltage
|
|
2kHz
|
1Hz
|
±(1%rdg + 2dgts)
|
100mVrms
|
600V
|
Diode (

)
|
Range
|
Resolution
|
Max. Test Current
|
Max. Open Circuit Voltage
|
Over Voltage Protection
|
|
|
1mV
|
1.5mA
|
3.5V
|
600V
|
Continuity (BEEPER)
|
Range
|
Resolution
|
Operation Resistance
|
Max. Open Circuit Voltage
|
Over Protection
|
|
|
0.1Ω
|
Below 100Ω
|
3.5V
|
600V
|
Capacitance (μF)
|
Range
|
Resolution
|
Accuracy
|
Max. Open Circuit Voltage
|
Over Protection
|
|
2000μF
|
1μF
|
±(5%rdg + 2dgts)
|
3.5V
|
600V
|
Peak Hold Measurement (23℃±5℃Below 80% RH)
AC Current
|
Range
|
Resolution
|
Accuracy (50Hz 60Hz)
|
Overload Protection
|
|
20A
|
10mA
|
±(2%rdg + 10dgts)
|
1000A
(Within 30 seconds)
|
|
200A
|
100mA
|
|
600A, 1000A
|
1A
|
AC Voltage
|
Range
|
Resolution
|
Accuracy(50Hz 60Hz)
|
Input Impedance
|
Overload Protection
|
|
600V
|
1V
|
±(1.5%rdg + 8dgts)
|
10MΩ
|
600V
|