Description
Electrical Specifications: (23℃±5℃)
DC Current:
| Range | Resolution | Accuracy | Overload Protection |
| 40A | 10mA | ±1.0%±2dgts | DC 400A |
| 0-150A | 100mA | ±1.0%±2dgts | |
| 150-200A | 100mA | ±2.2%±2dgts |
AC Current:
| Range | Resolution | Accuracy | Overload Protection | |
| 50/60 Hz | 40 – 1KHz | |||
| 40A | 10mA | ±1.0%±3dgts | ±1.5%±4dgts | AC 400A |
| 0-150A | 100mA | ±1.0%±3dgts | ±1.5%±4dgts | |
| 150-200A | 100mA | ±2.2%±3dgts | ±2.5%±4dgts | |
DC Voltage: (Input Impedance: 10MΩ)
| Range | Resolution | Accuracy | Overload Protection |
| 400V | 0.1V | ±1.0%±2dgts | DC 1000V |
AC Voltage:(Input Impedance: 10MΩ)
| Range | Resolution | Accuracy | Overload Protection | |
| 50/60 Hz | 40 – 1KHz | |||
| 400V | 0.1V | ±1.5%±2dgts | ±2.0%±4dgts | AC 800V |
Resistance (Ω) and Continuity: (open voltage 0.4V)
| Range | Resolution | Accuracy | Beeping | Overload Protection |
| 40-400Ω | 0.1Ω | ±1.0%±2dgts | < 40.0 Ω (approx.) | AC 600V |
Frequency: (Auto range)
| Range (Hz) | Resolution | Accuracy | Sensitivity | O.L Protection |
| 1-100K | 0.001 – 100 | ±0.5%±2dgts | 10V | AC 600V |
General Specifications:
| Conductor Size: | 23mm max. (approx.) |
| Dimension (Box): | 183 (L) x 63.6 (W) x 35.6 (H) mm
7.2″ (L) x 2.5″ (W) x 1.4″ (H) |
| Battery Type: | two 1.5V SUM-3 |
| Display: | 3 3/4 LCD with 40 seg. bargraph |
| Range Selection: | Manual |
| Overload Indication: | OL |
| Power Consumption: | 17 mA (approx.) |
| Low Battery Indication: | |
| Sampling Time: | 3 times/sec. (display)
30 times/sec. (bargraph) |
| Operating Temperature: | -10°C to 50°C |
| Operating Humidity: | less than 85% relative |
| Altitude: | up to 2000M |
| Storage Temperature: | -20°C to 60°C |
| Storage Humidity: | less than 75% relative |
| Weight: | 190g (battery included) |
| Accessories: | Carrying bag x 1
Users manual x 1 1.5V battery x 2 Test leads x 1 |