Description
The CM-02 Clamp Meter is designed for electricians, automotive technicians, and maintenance staff. Its 3 3/4 digit LCD display with a 40-segment bargraph provides clear readings. The meter supports both auto and manual range selection for versatile measurements.
It measures AC/DC current, voltage, resistance, frequency, capacitance, and temperature. The K-type thermocouple allows accurate temperature readings in Celsius or Fahrenheit. The 23 mm jaw fits easily into tight switch boxes or cable areas. Fast bargraph sampling at 30 times per second captures transient signals reliably. The meter also features one-touch zero for DC current, Max/Min recording, Data Hold, and auto power-off for battery saving.
Specifications
General Specifications:
| Conductor Size: |
23mm max. (approx.) |
| Dimension (Box): |
183 (L) x 63.6 (W) x 35.6 (H) mm
7.2″ (L) x 2.5″ (W) x 1.4″ (H) |
| Battery Type: |
two 1.5V SUM-3 |
| Display: |
3 3/4 LCD with 40 seg. Bargraph |
| Range Selection: |
Auto and Manual |
| Overload Indication: |
OL |
| Power Consumption: |
10 mA (approx.) |
| Low Battery Indication: |
|
| Sampling Time: |
3 times/sec. (display)
30 times/sec. (bargraph) |
| Auto-Power-Off: |
15 minutes |
| Operating Temperature: |
-10°C to 50°C |
| Operating Humidity: |
less than 85% relative |
| Altitude: |
up to 2000M |
| Storage Temperature: |
-20°C to 60°C |
| Storage Humidity: |
less than 75% relative |
| Weight: |
190g (battery included) |
| Accessories: |
Adapter (for Capacitance and K-type Thermal Couple) x 1
K-type Thermocouple x 1
Testing leads x 1
Carrying bag x 1
Users manual x 1
1.5V battery x 2 |
Electrical Specifications: (23℃±5℃)
DC Current:
| Range |
Resolution |
Accuracy |
Overload Protection |
| 40A |
10mA |
±1.5%±2dgts |
DC 400A |
| 0-150A |
100mA |
±1.5%±2dgts |
| 150-200A |
100mA |
±2.2%±2dgts |
AC Current:
| Range |
Resolution |
Accuracy |
Overload Protection |
| 50/60 Hz |
40 – 1KHz |
| 40A |
10mA |
±1.5%±3dgts |
±2.0%±4dgts |
AC 400A |
| 0-150A |
100mA |
±1.5%±3dgts |
±2.0%±4dgts |
| 150-200A |
100mA |
±2.2%±3dgts |
±2.5%±4dgts |
DC Voltage:(Overload Protection: 600V)
| Range |
Resolution |
Accuracy |
Input Impedance |
| 400mV |
0.1 mV |
±1.5%±3dgts |
2.3MΩ |
| 4V |
1 mV |
| 40V |
10 mV |
| 400V |
100 mV |
| 600V |
1V |
AC Voltage:(Input Impedance: 2.3 MΩ)
|
Range |
Resolution |
Accuracy |
Overload Protection |
| 50/60 Hz |
40 – 1KHz |
| 0.01 – 4V |
1mV |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
| 40V |
10mV |
| 400V |
100mV |
| 600V |
1V |
Frequency:
| Range (Hz) |
Resolution (Hz) |
Accuracy |
Sensitivity |
O.L Protection |
| 1-100K |
0.001–100 |
±0.5%±2dgts |
5V |
AC 600V |
Duty:
| Range (<10KHz) |
Resolution |
Accuracy |
Sensitivity |
| 1 – 99% |
0.1% |
10d |
10V |
Continuity:(Open circuit voltage 0.4V, Overload Protection AC 600V)
| Range |
Resolution |
Accuracy |
Beeper |
| 40-400Ω |
0.1Ω |
±1.0%±2dgts |
<10.0Ω (approx.) |
Resistance (Ω): (Open circuit voltage 0.4V)
| Range |
Resolution |
Accuracy |
Overload Protection |
| 400Ω |
0.1Ω |
±1.5%±2dgts |
AC 600V |
| 4KΩ |
1Ω |
| 40KΩ |
10Ω |
| 400KΩ |
100Ω |
| 4MΩ |
1KΩ |
| 40MΩ |
10KΩ |
Temperature:(K Type Thermal Couple with Adapter, ℃ or ℉ )
| Range |
Resolution |
Accuracy |
Overload Protection |
| -40 – 0 ℃ |
0.1 ℃ |
±2.0%±2 ℃ |
AC 600V |
| 0 – 400 ℃ |
0.1 ℃ |
±0.5%±2 ℃ |
| 400 – 1000 ℃ |
1 ℃ |
±0.5%±2 ℃ |
| -40 – 0 ℉ |
0.1 ℉ |
±2.0%±4 ℉ |
| 0 – 400 ℉ |
0.1 ℉ |
±0.5%±4 ℉ |
| 400 – 1800 ℉ |
1 ℉ |
±0.5%±4 ℉ |
Capacitance:
| Range |
Resolution |
Accuracy |
Overload Protection |
| 40nF |
10pF |
±5.0%±0.2 nF |
AC 600V |
| 400nF |
0.1nF |
±3.0%±0.2 nF |
| 4μF |
1nF |
±3.0%±0.02μF |
| 40μF |
10nF |
±3.0%±0.02μF |
| 400μF |
100nF |
±3.0%±0.2μF |
Diode Test:
| Range |
Resolution |
Accuracy |
Overload Protection |
| 0 – 1.999V |
0.001V |
±2.5%±5dgts |
AC 600V |