Hanna Instruments Boiler and Cooling Tower Photometer – HI83305

The HI83305 is a benchtop multi-parameter photometer with digital pH input designed specifically for boiler and cooling tower water analysis. Featuring an advanced 5-LED optical system with reference detector, it delivers highly accurate and repeatable results. With up to 30 programmed methods covering 18+ key water parameters, it ensures complete system monitoring. Integrated data logging (1000 readings), GLP tracking, and USB connectivity make it ideal for professional laboratory and industrial use.

  • 5 LED Optical System (420–610 nm) with Reference Detector for superior accuracy
  • Digital pH Electrode Input with Automatic Temperature Compensation
  • 30 Methods / 18+ Parameters for Boiler & Cooling Tower Monitoring
  • 1000 Data Logging Capacity + USB Export (.CSV Format)

Description

The HI83305 is engineered for comprehensive boiler and cooling tower water analysis, combining a professional photometer and digital pH meter in one compact benchtop unit. Its advanced optical system integrates five LEDs (420, 466, 525, 575, 610 nm) with narrow band interference filters (±1 nm accuracy), a beam splitter, silicon photodetector, and reference detector to ensure exceptional measurement stability. The reference detector compensates for drift caused by temperature fluctuations or power variation, delivering consistent results between blank and sample measurements. With support for up to 30 programmed methods measuring 18+ critical parameters, including dissolved oxygen, silica, ammonia, chlorine, phosphate, hydrazine, molybdenum, zinc, and more, the HI83305 provides total control over corrosion, scaling, and microbial growth risks.

Designed for traceability and efficiency, the HI83305 features a digital pH electrode input with stored calibration data inside the probe, allowing quick electrode changes without recalibration. Automatic temperature compensation ensures accurate pH readings under varying conditions. The instrument supports absorbance mode for custom method development and Beer-Lambert Law teaching applications, along with CAL Check validation. With 1000 data logging memory, GLP tracking, dual USB ports (USB-A and micro-USB-B), rechargeable Li-polymer battery operation, and CSV data export, this meter offers full laboratory functionality with industrial reliability.

Features

  • Advanced 5-LED Optical System: 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters (±1 nm accuracy).
  • Reference Detector with Beam Splitter: Compensates for drift caused by power fluctuation or temperature changes.
  • Digital pH Electrode Input: Stores calibration data inside probe with automatic temperature compensation.
  • 30 Pre-Programmed Methods: Measures 18+ key boiler and cooling tower parameters.
  • Absorbance Mode: Allows custom concentration vs absorbance plotting for user-developed chemistry.
  • Large 25 mm Cuvette Path Length: Improves accuracy especially in low absorbance samples.
  • Built-in Reaction Timer: Ensures consistent timing for photometric measurements.
  • Data Logging Capacity: Store up to 1000 readings with user ID and sample ID input.
  • GLP Tracking: Records calibration date, time, buffers, offset, and slope.
  • Dual USB Connectivity: USB-A for flash drive export and micro-USB-B for PC connection and power.
  • Rechargeable Battery: 3.7V Li-polymer battery supports >500 photometric tests or 50 hours pH use.
  • Backlit 128 x 64 Pixel LCD: Virtual keys and on-screen help for intuitive operation.

Specifications

SKU HI83305-02
Product Name Boiler and Cooling Tower Photometer – HI83305
Quote Required Yes
pH Range Photometer
pH Resolution Photometer
pH Accuracy Photometer
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV
Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2)
Dissolved Oxygen Resolution 0.1 mg/L
Dissolved Oxygen Accuracy ±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range 0.000 to 4.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy +/-0.003Abs @ 1.000 Abs
Aluminum Range 0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution 0.01 mg/L
Aluminum Accuracy ±0.04 mg/L ±4% of reading
Aluminum Method Adaptation of the aluminon method
Ammonia Range Low Range
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method
Chromium, Hexavalent Range Low Range
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.
Copper Range Low Range
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range
Copper Method Adaptation of the EPA bicinchoninate method
Hydrazine Range 0 to 400 μg/L (as N2H4)
Hydrazine Resolution 1 μg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method
Iron Range Low Range
Iron Resolution 0.001 mg/L; 0.01 mg/L
Iron Accuracy Low Range
Iron Method Low Range
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
Nitrate Range 0.0 to 30.0 mg/L (as NO3– N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
Nitrite Range Freshwater
Low Range
Nitrite Resolution Freshwater
Nitrite Accuracy Freshwater
Low Range
Nitrite Method Low Range
Oxygen, Scavenger Range 0 to 1000 μg/L (as DEHA)
0.00 to 1.50 mg/L (as Carbohydrazide)
0.00 to 2.50 mg/L (as Hydroquinone)
0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution 1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy ±5 μg/L ±5% of reading
Oxygen, Scavenger Method Adaptation of the iron reduction method
Phosphate Range Freshwater
Low Range
Phosphate Resolution Freshwater
Phosphate Accuracy Freshwater
Low Range
Phosphate Method Freshwater Low Range
Silica Range Low Range
Silica Resolution 0.01 mg/L; 1 mg/L
Silica Accuracy Low Range
Silica Method Low Range
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Input Channels 1 pH electrode input and 5 photometer wavelengths
pH Electrode digital pH electrode (not included)
Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detector silicon photodetector
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1 nm
Cuvette Type round, 24.6 mm
Number of Methods 128 max.
GLP calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Logging Type log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Weight 1.0 kg (2.2 lbs.)
Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8″)
Ordering Information HI83305 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.