Description
Main Features
| SCREEN DATA |
| Selected speed |
rpm |
| Selected spindle |
SP |
| Viscosity reading |
cP (mPa·s) or cSt |
| Percentatge of full scale |
% |
| Sampling temperature |
ºC or ºF |
| Shear Rate (with coaxial spindles) |
SR (s-1) |
| Shear Stress (with coaxial spindles) |
SS (N/m2) |
| Density (introduced by the user) |
g/cm3 |
| VISCOSITY READING |
| Dynamic viscosity |
cP or mPa·s |
| Kinematic viscosity |
cSt |
| Units Converter |
from SI to CGS |
| PROGRAM FEATURES |
| Time to torque: Ending of the test upon reaching a programmed torque |
| Time to stop: Ending of the test upon reaching a programmed time |
| 10 working memories |
| OTHER MAIN FEATURES |
| AUTO-TEST with visual and resonant alarm |
| AUTO-RANGE function |
| Temperature Reading through PT100 probe |
| User-enabled viscosity and temperature calibration |
| 10 language options |
| Port: USB |
| Software Datalogger: USB lets tranfer data to an Excel file in the PC |
Spindles
AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350
- BS: 6075, 5350
- ISO:2555,1652
- ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
Standard delivery
- The equipement is supplied complete with standard spindles
- 4 spindles for L model
- 6 spindles for R and H models
- Viscometer stand
- Spindle protector
- Temperature probe PT100
- Carring case
- USB cable
- Datalogger software
TECHNICAL SPECIFICATIONS
- Precision: +/- 1% full scale of range
- Resolution: For a minus viscosity of 10.000 cP : 0.1 cP For a major viscosity of 10.000 cP : 1 cP With the low viscosity adapter (LCP-LCP/B) : 0.01cP
- Repeatability: 0.2%
- Temperature probe features: Temperature limits: -10ºC to 150ºC 14ºF to 302ºF Resolution: 0.1ºC / -17.722 ºF Precision: +/- 0.2ºC / +/- 17.666 ºF Type of probe: PT100
- Supplied at 110-240VAC, 50/60 Hz.
ACCESSORIES
- APM : Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
- APM/B : Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
- LCP : Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- LCP/B : Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- HELDAL : Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
- THERMOSPHERE : Temperature control unit up to 300 ºC
| CODE |
MODEL |
MEASURING RANGE (CP) |
SPEED (R.P.M) |
NUMBER OF SPEEDS |
| VL210003 |
ADV L |
*1 – 2.000.000 |
0.3 – 100 |
18 |
| VL210002 |
ADV R |
100 – 13.000.000 |
0.3 – 100 |
18 |
| VL210001 |
ADV H |
200 – 106.000.000 |
0.3 – 100 |
18 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
PPRFast spindle switch (push plug and release)
| CODE |
MODEL |
MEASURING RANGE (CP) |
SPEED (R.P.M) |
NUMBER OF SPEEDS |
| VL211003* |
ADV L + PPR |
*1 – 2.000.000 |
0.3 – 100 |
18 |
| VL211002* |
ADV R + PPR |
25 – 13.000.000 |
0.3 – 100 |
18 |
| VL211001* |
ADV H + PPR |
200 – 106.000.000 |
0.3 – 100 |
18 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
Ranges
- (L) Low viscosity model
- (M) Medium viscosity model
- (H) High viscosity model
Low viscosity: The minimum viscosity when using a ‘L’ range with standard spindles is 10 cP * For measurements < 10cP, its recommended to use in conunction with the low viscosity adapter (LCP or LCP/B)