E-Sampler Dual Ambient Monitor/Sampler

Features:
  • Auto-Zero and Auto Span are programmable.
  • Automatic (1–65 000 m/m3).
  • Protocol for automatic flow control.
  • Inside Battery (30 Hours Operation without heater & 10 Hours with heater.).
  • Precision optical engine with laser diodes.
  • 47mm integral analysis filter
  • Temperature and atmospheric pressure.
  • A data logger inside.
  • Monitoring for PM10, PM2.5, PM1, and TSP.
  • Weatherproof Aluminum Enclosure.
  • Optics with purge-air protection.
  • Completely independent.
  • Filter replacement without tools.

Description

Specifications:

PARAMETER SPECIFICATION
Measurement Principles: Particulate concentration by forward light scatter laser Nephelometer. Integrated 47mm low flow gravimetric filter sampler.
Available Cut Points: TSP Inlet Standard. PM10, PM2.5, and PM1 sharp-cut cyclone inlets available.
Measurement Range: 0 to 65 mg/m3 (0 to 65,530 mg/m3) dynamic range. 16 bit digital range.
Nephelometer Accuracy: ± 10% to gravimetric method typical when K-factored to local particulate type.
Gravimetric Accuracy: ± 8% of NIOSH 0600.
Precision: Greater of 3 µg/m3 or 2%.
Data Storage Resolution: 1 µg/m3
Data Storage Intervals: User-Selectable 1, 5, 10, 15, 30, or 60 minute averages.
Nephelometer Interval: 1-second measurements, available on analog output and display.
Sample Cycles: Continuous operation or programmable scheduled sample runs.
Particle Size Sensitivity: 0.1 to 100 micron. Optimal sensitivity 0.5 to 10 micron particles.
Laser Type: Diode Laser, 5 mW, 670nm. Visible red.
Long Term Stability: 5% with clean optics.
Flow Rate: 2.0 liters/minute ± 0.1 lpm. Actual volumetric flow.
Pump Type: 10,000 hour brushless diaphragm sample pump and secondary purge pump.
Gravimetric Filter Type: 47mm disc filters (not included). Accepts standard FRM filter holder cartridges.
Automatic Zero and Span: User-selectable 15 min, 1 hour, 2 hour, 12 hour, or 24 hour intervals. 2.8 min cycle.
Internal Battery: Optional lead acid battery, 12V, 12 Amp-Hour. Yuasa NP12-12 or equivalent.
Internal Battery Run Time: Up to 30 hours with inlet heater off. Up to 10 hours with inlet heater on.
Power Supply: Universal 100-240 VAC input, 15 VDC output power supply included. Compatible with solar power kits or external batteries using optional DC power cable.
Power Consumption: 1.1 amps @ 12 VDC (15 Watts) max continuous draw, running with inlet heater on.

0.35 amps (4.2 Watts) running with inlet heater off.

Operating Temperature: 0 to +50°C . (Ambient Temperature Sensor Range -30 to +50°C).
Barometric Pressure: 60,000 to 104,000 Pascal pressure sensor range.
Ambient Humidity Range: 0 to 90% RH, non-condensing.
Humidity Control: Automatic 10 Watt inlet heater module controlled to sample RH setpoint. Sample RH sensor standard. Optional EX-593 ambient RH sensor available.
Approvals: CE, ISO-9001. Designed to agree with EPA Class I and Class III FRM/FEM particulate samplers and monitors. Not an EPA-designated equivalent method.
User Interface: Menu-driven interface with 4×20 character LCD display and dynamic keypad.
Analog Voltage Output: 0-1, 0-2.5, or 0-5 volt DC output. User-set range with 1-second real-time output.
Serial Interface: RS-232 2-way serial port for PC, datalogger, or modem communications.
Alarm Contact Closure: Normally closed contact closure relay output. Contact rating 0.5A @ 100V DC max.
Compatible Software: Comet™ (included), Air Plus™, terminal programs such as HyperTerminal®
Alarm Reporting: Available through serial port data files, display, and relay output.
Memory: 4369 data logger records (182 days @ 1 record/hr, 3 days @ 1 record/min).
Factory Service Interval: 24 Months typical, under continuous use in normal ambient air.
Mounting Options: Pole or wall mount bracket standard. Optional EX-905 tripod recommended.
Unit Weight: 6.4 kg (14 lbs) without tripod, battery, or optional accessories.
Unit Dimensions: 65cm high, 27cm wide, 16.5cm deep. (25.5” x 10.5” x 6.5”). With inlet assembly