Hanna Instruments HI2030 edge® Multiparameter EC/TDS/Salinity Meter

The result of Hanna’s vision, design skills, integrated production, and top-notch R&D is edge’s ground-breaking design. Although the edge meter is only 0.5″ thick, it is packed with functions to meet the needs of a wide range of clients.

There is a basic mode operation with a streamlined menu and options for people who choose extremely simple operation, and a full featured standard operating mode for those who require extensive functions. You can add more probes to the edge HI2030 EC/TDS/Salinity kit at any moment to detect pH or dissolved oxygen.

Description

In Cradle

Edge employs sophisticated digital electrodes with an integrated microchip that maintains calibration data and immediately transfers it to the meter when it is connected.

Digital Electrodes

Digital Electrodes

With a built-in microchip that maintains calibration data and is immediately accessed by edge once the electrode is plugged in, edge electrodes are extremely sophisticated. Additionally, the 3.5 mm connector on these digital electrodes makes it simple to attach them, so you never have to worry about the pins being lined up correctly.

 

Digital Electrodes

Four Ring Probe

The HI763100 four ring platinum conductivity probe, which has an integrated temperature sensor for automatically temperature-corrected data, is included with the HI2030 edge EC/TDS/Salinity meter. In contrast to amperometric two pole probes, which have a constrained range and are susceptible to polarization effects, the four ring technique enables a large range of measurements with a single probe. The body of the HI763100 probe is made of glass and PVDF, and the sleeve is PEI (polyetherimide). Both materials exhibit outstanding resistance to a variety of corrosive substances.

 

3.5mm Probe Input

3.5 mm Probe Input

It has never been easier to attach an electrode; there are no alignment requirements and no damaged pins; simply connect the 3.5 mm connector and begin going.

Mounted

 

edge® is remarkably adaptable. Without taking up the space of a conventional tabletop meter, it can be used in a variety of settings and methods.

wall mount

Wall Mount

Edge can be mounted to a wall using the provided wall mount cradle, leaving no footprint on the available benchtop area. A built-in connector in the cradle powers the edge and charges its batteries. Edge’s minimal footprint is intended to help you free up valuable worksurface area.

 

Cradle

Cradle and Electrode Holder

The edge has a tabletop cradle with an adjustable swivel electrode holder that holds the edge firmly at the ideal viewing angle while it charges.

 

sides

 

edge® has a battery life of 8 hours, weighs about 8.8 oz., and has two USB connections.

usb

 

Two USB Ports

Edge has two USB ports: a conventional USB connector for transferring data to a flash drive and a second micro USB port for charging your device when the cradle is not accessible and connecting to a computer to transfer files.

data logging

Data Logging

You can save up to 1000 log records of data on edge. Data can be logged at predetermined intervals, on stability (200 records), or on demand (200 recordings) (600 records). Current reading, date, time, and GLP data are among the items that are kept.

 

basic mode

 

Basic Mode

Both Basic and Standard Modes are available on edge. The edge as an EC meter lowers features in Basic Mode to make operation simpler. The meter’s only automatic functions in Basic Mode are automatic temperature adaptation, automatic reading range, and automatic cell factor correction during calibration. There is no interval logging and the temperature compensation coefficient is fixed at 1.9% / oC. The user can modify these features in Standard mode.

More Information
SKU HI2030-02
Product Name edge® Multiparameter EC/TDS/Salinity Meter – HI2030
Quote Required Yes
pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*
pH Resolution 0.01 pH, 0.001 pH*
pH Accuracy ±0.01pH, ±0.002 pH*
pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*
pH Temperature Compensation Automatic -5 to 100º C (23 to 212º F) (using integral temperature sensor)
EC Range 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡
EC Resolution 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 Cell Factor calibration; 6 standards available
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF); NoTC – can be selected to measure absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity (% NaCl) Range 0.0 to 400.0% NaCl *
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU *
Salinity (PSU) Resolution 0.01 PSU,
Salinity (PSU) Accuracy ±1% of reading
Salinity Range 0.0 to 80.0 g/L *
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading
Dissolved Oxygen Measurement Type polarographic
Dissolved Oxygen Range 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%
Dissolved Oxygen Resolution 0.01 ppm (mg/L), 0.1%
Dissolved Oxygen Accuracy ±1.5% of reading
Dissolved Oxygen Calibration One or two points at 0% (HI 7040) and 100% (water saturated air)
Dissolved Oxygen Temperature Compensation 0.0 to 50.0 ºC (32.0 to 122 ºF)
Salinity Compensation 0 to 40 g/L 1 g/L
Altitude Compensation -500 to 4,000 m (-1640 to 13120’) 100 m (328’)
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±1.0 °F
EC/TDS Probe HI 763100 EC/temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)