Hanna Instruments HI9813-6 Portable pH/EC/TDS/Temperature Meter with CAL Check™

The affordable, water-resistant HI9813-6 portable meter detects temperature, pH, conductivity (EC), and total dissolved solids (TDS) with a single probe. The Hanna Instruments CAL Check is a function of the HI9813-6 that lets the user know when the probe needs to be calibrated or changed. With specific buttons for measurement modes to be presented on the LCD and knobs for single point pH and EC calibration, the meter’s operation is made simpler.
Based on the actual EC value, the HI9813-variable 6’s EC to TDS conversion factor automatically shifts from 0.56 to 0.78 ppm = 1 S/cm. This product line is appropriate for hydroponic, greenhouse, and agricultural uses. The fixed value of the temperature correction coefficient () is 2%/°C.
  • 3 in 1 probe with pH, EC/TDS and temperature sensors
  • Amplified pH electrode for immunity to electrical noise including from ballasts and pumps
  • CAL Check

Description

More Information
SKU HI9813-6
Product Name Portable pH/EC/TDS/Temperature Meter with CAL Check™ – HI9813-6
Quote Required Yes
pH Range 0.0 to 14.0 pH
pH Resolution 0.01 pH
pH Accuracy ±0.1 pH
pH Calibration manual, 1-point through offset trimmer
EC Range 0.00 to 4.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy ±2% F.S.
EC Calibration manual, 1-point through slope trimmer
TDS Range 0 to 1999 ppm (mg/L)
TDS Resolution 1 ppm (mg/L)
TDS Accuracy ±2% F.S.
TDS Calibration manual, 1-point through slope trimmer
EC/TDS Temperature Compensation automatic from 0 to 50°C (32 to 122°F)
Temperature Correction Coefficient β=2%/°C typical
EC to TDS Conversion Factor variable based on reading from 0.56 to 0.72 according to the TDS 442 curve for natural water
Temperature Range 0.0 to 60.0°C / 32.0 to 140.0°F
Temperature Resolution 0.1°C
Temperature Accuracy ±0.5°C /±1°F
Multi-parameter Probe HI 1285-6 combination, amplified pH/EC/TDS/temperature probe with Cal-Check feature, built-in temperature sensor, 8-pin DIN connector and 1 m (3.3′) cable
Battery Type/Life 9V / approximately 150 hours of continuous use
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 145 x 80 x 36 mm (5.7 x 3.1 x 1.4”)
Weight 230 g (8.1 oz)
Ordering Information HI9813-6 is supplied with HI1285-6 pH/EC/TDS/°C probe with Cal-CheckTM, HI70007 pH 7.01 buffer solution sachet (1), HI70442 1500 ppm calibration solution sachet (1), HI70031 1413 µS/cm calibration solution sachet (1), HI700661 electrode cleaning solution sachets (2), HI50021 calibration check solution sachets (2), 9V battery, instructions and rugged carrying case.