| SKU |
HI98494-web |
| Product Name |
Multiparameter Bluetooth® Portable pH/EC/OPDO Meter – HI98494 |
| Quote Required |
Yes |
| pH Range |
0.00 to 14.00 pH* |
| pH Resolution |
0.01 pH |
| pH Accuracy |
± 0.02 pH |
| pH Calibration |
One point (HI9828-25 Quick calibration solution); up to three points using five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) and one custom buffer |
| pH Temperature Compensation |
Automatic from -5 to 50 °C (23 to 122 °F) |
| ORP Range |
± 2000.0 mV |
| ORP Resolution |
0.1 mV |
| ORP Accuracy |
± 1.0 mV |
| ORP Calibration |
One point (relative mV) |
| mV Range (pH in mV) |
± 600.0 mV |
| mV Resolution |
0.1 mV |
| mV Accuracy |
± 0.5 mV (Relative Offset) |
| EC Range |
0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Resolution |
Auto-ranging |
| EC Accuracy |
± 1% of reading or ± 1 μS/cm, whichever is greater |
| EC Calibration |
One point (HI9828-25 Quick calibration solution); one point using six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range |
0 to 400000 ppm (mg/L) |
| TDS Resolution |
Manual |
| TDS Accuracy |
± 1% of reading or ± 1 ppm (mg/L), whichever is greater |
| TDS Calibration |
Based on conductivity calibration |
| EC/TDS Temperature Compensation |
Automatic from -5 to 50 °C (23 to 122 °F) |
| Temperature Correction Coefficient |
0.00 to 6.00 %/°C |
| EC to TDS Conversion Factor |
0.00 to 1.00 |
| Reference Temperature |
20 °C or 25 °C |
| Cell Type |
Potentiometric four pole |
| Multi-range Measurement Modes |
Yes |
| Salinity (PSU) Range |
0.00 to 70.00 PSU |
| Salinity (PSU) Resolution |
0.01 PSU |
| Salinity (PSU) Accuracy |
± 2% of reading or ± 0.01 PSU, whichever is greater |
| Salinity (PSU) Calibration |
One point using custom solution |
| Salinity (Seawater Sigma) Range |
0.0 to 50.0 σt, σ0, σ15 |
| Salinity (Seawater Sigma) Resolution |
0.1 σt, σ0, σ15 |
| Salinity (Seawater Sigma) Accuracy |
± 1.0 σt, σ0, σ15 |
| Salinity (Seawater Sigma) Calibration |
Based on conductivity or salinity calibration |
| Resistivity Range |
0 to 999999 Ω·cm |
| Resistivity Resolution |
1 Ω·cm; 0.1 kΩ·cm; 0.0001 MΩ·cm |
| Resistivity Calibration |
Based on conductivity or salinity calibration |
| Dissolved Oxygen Measurement Type |
Optical luminescent technology |
| Dissolved Oxygen Range |
0.00 to 50.00 mg/L; 0.0 to 500.0 % saturation |
| Dissolved Oxygen Resolution |
0.01 mg/L; 0.1 % saturation |
| Dissolved Oxygen Accuracy |
± 1.5% of reading ± 0.01 mg/L (0–20 mg/L); ± 5% of reading (20–50 mg/L); ± 1.5% ±0.1% (0–200%); ± 5% (200–500%) |
| Dissolved Oxygen Calibration |
Quick calibration in water-saturated air; one or two points (100% and 0%); or custom solution |
| Dissolved Oxygen Temperature Compensation |
Automatic from -5 to 50 °C (23 to 122 °F) |
| Altitude Compensation |
Automatic |
| Temperature Range |
-5.00 to 50.00 °C; 23.00 to 122.00 °F; 268.15 to 323.15 K |
| Temperature Resolution |
0.01 °C; 0.01 °F; 0.01 K |
| Temperature Accuracy |
± 0.15 °C; ± 0.27 °F; ± 0.15 K |
| Temperature Calibration |
One point using custom value |
| Logging Type |
Interval and log on demand |
| Logging Memory |
50,000 records (interval); 20,000 records (log-on-demand) |
| Logging Interval |
1 second to 3 hours |
| Connectivity |
Bluetooth®, USB-C (mass-storage host/device) |
| Automatic Shut-Off |
5, 10, 15, 20, 30, 60 minutes or disabled |
| GLP |
Yes |
| Display |
Backlit dot matrix |
| Battery Type / Life |
Minimum 200 hours (AA batteries); Minimum 50 hours (Li-ion battery) |
| IP Protection |
IP67 |
| Environment |
0 to 50 °C (32 to 122 °F); RH 100% |
| Dimensions |
185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
| Weight |
435 g (13.3 oz) |
| Atmospheric Pressure Range |
450.0 to 850.0 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution |
0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy |
±3.0 mmHg within ±15°C from calibration temperature |
| Atmospheric Pressure Calibration |
One point using custom value |
| Ordering Information |
Supplied with HI7698494 multi-sensor probe, HI7698194-1 pH/ORP sensor,
HI7698194-3 EC/TDS/Resistivity/Salinity sensor, HI7698494-5 optical DO sensor,
HI764113-1 DO smart cap, calibration beaker, quick calibration solution,
zero oxygen solution set, maintenance kit, USB cable, AA batteries (4),