TES AC/DC 2000A Power Clamp Meter PROVA-6600

PROVA-6600
AC/DC 2000A Power Clamp Meter
Product Features
  • Power measurements of 34W, 33W, 3 balanced, 12W, and 13W
  • True AC+DC power ranges from 0 to 1200KW (AC 600V, DC 800V, and ACA/DCA 2000A).
  • True RMS AC+DC voltage range: 0 to 600V
  • True RMS AC+DC current: 0 to 2000A
  • AC+DC 2000KW (3), and AC+DC 1200KW (1).
  • V+Hz, A+Hz, W+PF, KVA+KVAR, and V+A on a dual display
  • Phase angle calculation
  • frequency calculation
  • RST(L1L2L3) Sequence Indication, position 3
  • four records in memory
  • moment the power clamp is turned on, DCA/DCW automatically zeros
  • Auto-detection of AC/DC
  • Auto range
  • Jaw size: 55 mm
  • Low battery warning

Description

Electrical Specifications: (23℃±5℃)

AC+DC True Power: PF 0.2 – 1.0, 3∅3W, 34W, 12W, and 13W)

Range Resolution Accuracy (of reading) Range
0 – 99.99KW 0.01KW ±2.0%±0.05KW AC 600V, DC 800V, ACA/DCA 2000A

 

100 – 999.9KW 0.1KW ±2.0%±0.5KW
1000-1200KW 1KW ±2.0%±5KW

KW Autoranging Map: (PF 0.2 – 1.0, 33W, 34W, 12W, and 13W)

  0V – 200V 200V – 600VAC, 200V – 800VDC
0A – 200A 0.00 – 40.00KW 0.00 – 99.99KW, 100.0 – 160.0KW
200A – 2000A 0.0 – 400.0KW 0.0 – 999.9KW, 1000 – 1600KW

AC+DC True Power: (Power Factor 0.2 – 1.0, 3Balanced Power)

Range Resolution Accuracy(of reading) Range
0 – 99.99KW 0.01KW ±2.0%±0.5KW AC 600V, DC 800V, ACA/DCA 2000A

 

100 – 999.9KW 0.1KW ±2.0%±0.5KW
1000-1200KW 1KW ±2.0%±5KW

AC+DC Voltage:

(True RMS, Crest Factor<4, Auto range, Overload Protection  800VAC for all ranges.)

Range Resolution Accuracy (of reading) Input Impedance
DC, 50/60 Hz 40 – 400Hz
0-200V 0.1V ±1.5%±5dgts ±2.0%±5dgts 10MΩ
200-500V 0.1V ±1.5%±5dgts ±2.0%±5dgts 10MΩ
500-600V 1V ±1.5%±5dgts ±2.0%±5dgts 10MΩ

AC+DC Current: (True RMS, Crest Factor < 4)

Range Resolution Accuracy (of reading) Overload Protection
DC, 50/60 Hz 40 – 400Hz
0-200A 0.1A ±1.5%±5dgts ±2.0%±5dgts AC 3000A
200-500A 0.1A ±2.0%±5dgts ±2.5%±5dgts AC 3000A
500-2000A 1A ±2.5%±5dgts ±3.0%±5dgts AC 3000A

Phase Angle: (50/60 Hz, must zero current reading before measurement)

Range Accuracy Sensitivity Remark
-90° to +90° ± 2.0° V > 100V, A > 10A Zero Crossing Detection

Frequency: (if < 10 Hz, Hz = 0)

Range Accuracy Sensitivity
50/60 Hz ±2digits V: > 1V, A: > 5A
10 – 400 Hz 0.5% ± 2 digits V: > 1V, A: > 5A

 

General Specifications: 

Conductor Size: Cable 55mm. (approx.)

Bus Bar 65mm(D) x 24mm(W)

Battery Type: 9V
Display: 2 X 4 Digits Dual Display LCD
Range Selection: Auto
Overload Indication: OL
Power Consumption: 25mA (approx.)
Low battery Indication:
Sampling Time: 0.5 sec. (V and A)

1.6 sec. (W)

Operating Temperature: C to 50°C
Operating Humidity: less than 85% relative
Altitude: up to 2000M
Storage Temperature: -20°C to 60°C
Storage Humidity: less than 75% relative
Dimension: 271mm (L) x 112mm (W) x 46mm (H)

10.7″ (L) x 4.4″ (W) x 1.8″ (H)

Weight: 647g / 22.8 oz (battery included)
Accessories: Carrying bag x 1

Users manual x 1

Battery 9V x 1, installed