Description
The AC/DC 1000A Power Clamp Meter is a high-precision instrument designed for measuring true power, apparent power, and power factor, along with AC/DC voltage and current. It features dual 4-digit LCD displays with a 40-segment bargraph for easy visual interpretation of measurements. The meter supports peak detection, crest factor analysis, and frequency measurement up to 5 kHz, with programmable MIN/MAX data logging.
Equipped with an alkaline battery, it provides approximately 30 hours of operation. The clamp opening accommodates cables up to φ46 mm. The meter offers comprehensive overload protection for voltage (600 Vrms) and current (1100A), and operates reliably under temperatures from 0°C to 50°C with relative humidity below 80%. Optional PC connectivity and software allow data logging and analysis.
Ideal for power analysis, load testing, electrical troubleshooting, and on-site energy monitoring.
Specifications
GENERAL SPECIFICATIONS :
| Specification |
Details |
| Maximum Voltage (to earth ground) |
600 Vrms |
| Numerical Dual Display |
4-digit LCD, maximum reading 9999 |
| Bargraph Display |
40 Segments |
| Battery Life |
Approx. 30 hours (Alkaline) |
| Jaw Opening Diameter |
Cables φ46 mm |
| Operating Temperature & Humidity |
0°C to 50°C (32°F to 122°F), R.H. < 80% non-condensing |
| Storage Temperature & Humidity |
-10°C to 60°C (14°F to 140°F), R.H. < 70% non-condensing |
| Dimensions (L × W × H) |
260 mm × 93 mm × 45 mm |
| Weight |
Approx. 450 g |
| Accessories |
Carrying Case, Test Leads, Battery, Instruction Manual |
ELECTRICAL SPECIFICATIONS :
⊕ TRUE power & Apparent power measurement
| Input |
Resolution |
Accuracy |
Frequency
range |
Overload protection |
| V |
0.01 |
±(2%+5) |
45Hz~ 500Hz |
600V/1100A |
| V>130V , A<150A |
| V150A |
| V>130V , A>150A |
0.1 |
±(2%+1) |
⊕ DCA
| Range |
Resolution |
Accuracy |
Overload protection |
| 5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
1100A |
⊕ ACA
| Range |
Resolution |
Accuracy |
Frequency range |
Overload protection |
| 5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
45Hz~500Hz |
1100A |
※ Crest Factor :
⊕ DCV
| Range |
Resolution |
Accuracy |
Input
Impedance |
Overload protection |
| 5 ~ 600V |
0.1V |
±(0.5%rdg+5dgts) |
1MΩ |
600V |
⊕ ACV
| Range |
Resolution |
Accuracy |
Input Impedance |
Frequency Range |
Overload protection |
| 5 ~ 600V |
0.1V |
± ( 0.5%rdg + 5dgts) |
1MΩ |
45Hz~500Hz |
600Vrms |
※Crest Factor : 3 for stated accuracy
⊕ Peak Indication:
| Range |
Resolution |
Accuracy |
Overload protection |
| 20A~80A |
0.1A |
±(10%rdg+10dgts) |
1100A |
| 80A~1000A |
±(6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
⊕ Peak Indication:
| Range |
Resolution |
Accuracy |
Overload protection |
| 20V~80V |
0.1V |
±(10%rdg+10dgts) |
600Vrms |
| 80V~600V |
±( 6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
⊕ Audible continuity
| Range |
Continuity beeper |
Open circuit voltage |
Overload protection |
| |
≦ 0.050 |
≦3.2V |
600Vrms |
⊕ Resistance ( Ω )
| Range |
Resolution |
Accuracy |
Open circuit
voltage |
Overload protection |
| 10KΩ |
1Ω |
±( 1 ﹪rdg + 5dgts) |
≦ 3.2 V |
600Vrms |
⊕ Diode test
| Range |
Resolution |
Overload protection |
| |
0.001V |
600Vrms |
⊕ Frequency ( Hz )
| Range |
Resolution |
Accuracy |
Voltage sensitivity |
Overload protection |
| 1KHz |
0.1Hz |
±(0.5﹪rdg+5dgts) |
10V or 10A |
600V / 1100A |
| 5KHz |
1Hz |
⊕ Optional Accessories: