Specifications:
| Property | Value |
|---|---|
| No. of measurement series | 500 |
| Measurement memory | 250.000 readings |
| Statistical functions | Number of readings · Minimum · Maximum · Mean value · Standard deviation · Coefficient of variation · Block statistics (Standard or free configurable) · Cp · Cpk · Histogram · Trend diagram |
| Calibration | 1-point calibration (Zero) 2-point calibration multi point calibration with up to 5 points |
| Additional calibration procedures according to international standards | ISO 19840:2004(E) SSPC-PA2 SS 184160 AS 3894.3 |
| Limit monitoring | Optical and acoustical signaling |
| Measurement units | metric: µm · mm · cm imperial: mils · inch · thou |
| Data interface | USB (via adaptor) IrDA® (Infrared) RS-232 (via adaptor) |
| Printer | Standard ASCII printer Wireless ElektroPhysik printer |
| International standards | DIN EN ISO 1461 · DIN EN ISO 2064 · DIN EN ISO 2178 · DIN EN ISO 2360 · DIN EN ISO 2808 · DIN EN ISO 3882 · ISO 19840 · ASTM B 244 · ASTM B 499 · ASTM D 7091 · ASTM E 376 · AS 3894.3 · SS 184160 · SSPC-PA 2 · IMO-PSPC |
| Display | graphics display, adjustable lighting |
| Power supply | 4 x batteries AA / LR 06 / Mignon Mains adaptor 90 – 240V / 48 – 62 Hz |
| Operating temperature range | -10 °C … +60 °C / 14 °F … 140 °F |
| Storage temperature range | -20 °C … +70 °C / -4 °F … 158 °F |
| Dimensions | 153 mm x 89 mm x 32 mm 4.84″ x 3.5″ x 1.26″ |
| Weight | 310 g / 10.93 oz (incl. batteries) |