The Met One 010C and 020D sensors provide accurate wind speed and wind direction measurements for environmental and meteorological applications. Built with durable anodized aluminum, these IP65-rated sensors offer low starting thresholds, quick response times, and field-serviceable electronic components, making them ideal for long-term outdoor monitoring.

  • High Accuracy & Range: 010C measures wind speed up to 60 m/s (125 mph) with ±1% accuracy; 020D measures wind direction 0–360° with ±3° accuracy.
  • Durable & Weatherproof: Both sensors feature anodized aluminum housing with IP65 protection, suitable for extreme temperatures (-50°C to +85°C).
  • Quick Response & Low Threshold: 010C starts measuring at 0.27 m/s; 020D has a 0.6 mph threshold with minimal delay distance and high damping.
  • Field-Serviceable & Easy Installation: Internal heater prolongs bearing life, electronic components can be replaced in the field, and sensors mount easily on crossarms with quick-detach connections.

Description

The Met One 010C Wind Speed Sensor and 020D Wind Direction Sensor are precision instruments designed for accurate and reliable monitoring of wind conditions in harsh environments. The 010C anemometer measures wind speeds up to 60 m/s (125 mph) with a starting threshold as low as 0.27 m/s (0.6 mph) and an accuracy of ±1 % or 0.15 mph. Its fast response time, with a distance constant under 5 ft of flow, allows it to capture rapid gusts, while the optional aluminum cupset extends performance for turbulent conditions. The sensor operates in temperatures from −50 °C to +85 °C, draws minimal power (12 VDC at 10 mA), and is housed in anodized aluminum for durability. Features like a built-in heater ensure long bearing life, and the sensor is designed to reduce turbulence effects, making it ideal for environmental monitoring and research stations.

The 020D Wind Direction Sensor provides precise azimuth measurements from 0–360° with electrical linearity of ±0.5 % and an accuracy of ±3°. Its low threshold of 0.6 mph and short delay distance of under 3 ft ensure rapid response to changing wind directions. The sensor supports selectable voltage outputs (0–5 V or 0–2.5 V), operates over −50 °C to +85 °C, and comes in a rugged anodized aluminum housing with IP65 protection. With features like elevated damping, quick-detach connections, and field-replaceable electronics, the 020D complements the 010C for a complete and reliable wind monitoring solution in both research and operational meteorological applications.

Features

  • Low threshold for entry.
  • Long bearing life thanks to internal heater.
  • Slender to reduce “sensor turbulence”.
  • Elevated damping ratio.
  • A short delay time.
  • Connection with quick detach.
  • Electronic parts that can be changed in the field.
  • Level 65 of Ingress Protection (IP65).

Specifications

Model 010C Wind Speed Sensor Specifications
Performance Characteristics
Maximum Operating Range 0-60 meters/sec or 0-125 mph
Starting Speed 0.27 meters/sec or 0.6 mph
Calibrated Range 0-50 meters/sec or 0-100 mph
Accuracy 1% or 0.15 mph
Temperature Range -50C to +85C
Response Distance constant less than 5 ft of flow*
The distance traveled by the air after a sharp-edged gust has occurred for the

anemometer rate to reach 63% of the new speed. Distant constant less than 15ft of

flow with optional 010C-1 aluminum cupset.

Electrical Characteristics
Power Requirements 12 VDC at 10 mA
Output Signal 11-volt pulse
Output Impedance 100 ohms maximum
Heater Power Requirement 12 VDC at 350 mA
Standard Cable Length 300’ maximum (consult factory if longer cable is to be used for special requirements)
Physical Characteristics
Weight 1.1 pounds
Finish Anodized aluminum
Mounting Use with 191 Crossarm
Cabling 1953-XX Cable (XX is cable length in feet)

 

Model 020D Wind Direction Sensor Specifications
Performance
Azimuth Electrical 0-356, Mechanical 0-360
Threshold 0.6 mph
Linearity  ½% of full scale
Accuracy 3
Damping Ratio 0.4
Delay Distance Less than 3 feet
Temperature Range -50C to +85C
Electrical Characteristics
Input Power 9-18 VDC, 10 mA
Output* a. 0-5 volts for 0-360 (default setting)

b. 0-2.5 volts for 0-360 (user selectable)

Output Impedance 100 Ohms maximum
Maximum Cable Length 300 feet
Physical Characteristics
Weight 1.1 pounds
Finish Anodized Aluminum
Mounting Use with Crossarm Model 191 or equivalent
Cabling 1957-XX Cable (XX is cable length in feet)