Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES TES-3010A Digital Clamp Meter

The TES-3010A Digital Clamp Meter measures AC current, DC/AC voltage, resistance, frequency, and diode/continuity with high accuracy. It features peak hold, data hold, and low battery indication for reliable field testing.

  • AC Current Range: 20A / 200A / 600A (True RMS)
  • DC/AC Voltage: 0–600V
  • Resistance Measurement: 200Ω / 20kΩ
  • Frequency: 10Hz–2kHz

Description

The TES-3010A Digital Clamp Meter is designed for technicians and electricians needing accurate measurements in the field. It handles AC and DC current from 20A to 600A, voltage up to 600V, and resistance and continuity testing. The meter also measures frequency and diode functionality, making it a versatile tool for multiple applications.

Its peak hold and data hold functions allow users to capture transient values quickly. A clear LCD display ensures easy reading, while a low battery indicator prevents interruptions during critical measurements. The meter is rated CAT II 1000V / CAT III 600V, offering enhanced safety for high-voltage environments.

The compact design and included carrying case and test probes make this clamp meter ideal for telecommunication, electrical, and industrial maintenance. With a fast response rate and accurate readings, it simplifies troubleshooting in crowded switch boxes, panel boards, or cable installations.

Features

  • Measures AC/DC current and voltage

  • Resistance, continuity, frequency, and diode testing

  • Peak hold and data hold functions

  • Low battery warning

  • Compact and lightweight for field use

  • CAT II 1000V, CAT III 600V safety ratings

Specifications

ELECTRICAL SPECIFICATION:

  AC Current

Range Resolution Accuracy (50Hz/60Hz) Overload Protection
20A 10mA ±(2%rdg + 5dgts) 1000A

(Within 30 seconds)

200A 100mA
600A 1A

  DC Voltage

Range Resolution Accuracy Input Impedance Overload Protection
600V 1V ±(0.8%rdg + 2dgt) 10MΩ 600V

   AC Voltage

Range Resolution Accuracy (40Hz-400Hz) Input Impedance Overload Protection
200V 100mV ±(1.2%rdg + 3dgts) 10MΩ 600V
600V 1V

Resistance (Ω)

Range Resolution Accuracy Max. Open Circuit Voltage Overload Protection
200Ω 100mΩ ±(1%rdg + 2dgts) 3.5V 600V
20KΩ 10Ω 0.3V

Frequency (Hz) (10Hz-2KHz)

Range Resolution Accuracy Max. Input Sensitivity Max. Allowable Applied Voltage
2KHz 1Hz ±(1%rdg + 2dgts) 100mV 600V

Diode (   )

Range Resolution Max. Test Current Max. Open Circuit Voltage Over Voltage Protection
1mV 1.5mA 3.5V 600V

Continuity (BEEPER)

Range Resolution Operation Resistance Max. Open Circuit Voltage Over Protection
0.1Ω Below 100Ω 3.5V 600V

Peak Hold Measurement (23±5Below 80% RH)

AC Current

Range Resolution Accuracy (50Hz 60Hz) Overload Protection
20A 10mA ±(2%rdg + 10dgts) 1000A

(Within 30 seconds)

200A 100mA
600A 1A

AC Voltage

Range Resolution Accuracy (50Hz 60Hz) Input Impedance Overload Protection
200V 100mV ±(1.5%rdg + 8dgts) 10MΩ 600V
600V 1V
  • Operating Temperature: 0℃~40℃, 0-80% RH.GENERAL SPECIFICATION:
  • Sampling Rate: 2.5 times per second.
  • The time of peak Value Response: about 100ms.

  Power Source: 006P DC 9V 1pc.

  Size & Weight: 208mm×65mm×31mm & 308g.

  Accessories: Test probe 1 pair, Instruction Manual, Carrying Case, Battery.

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.