Description
| Battery Types Tested | Compact storage batteries, Alkali and lead-acid batteries. | ||||
| Battery Capacity | 0 to 1200AH | ||||
| Resistance | Ranges : 4mΩ,40mΩ,400mΩ,4Ω,40Ω,400Ω
Resolution : 1μΩ,10μΩ,100μΩ,1mΩ,10mΩ,100mΩ Accuracy : ±(3%reading ± 20digits) on 4mΩrange. ±(0.8%reading ± 6digits) on 4mΩother ranges. |
||||
| Measurement Condition | Current : Approx. 40mA,4mA,400μA, 40μA,4μA
Frequency : 1kHz±30Hz |
||||
| DC Voltage | Range : 6V, 60V
Resolution : 1mV, 10mV Accuracy : ±(0.1%rdg±6digits) |
||||
| Temperature | Range : -20°C to 60°C (-4°F to 140°F)
Resolution :0.1°C / 0.1°F Accuracy : ±1°C / ±1.8°F |
||||
| DC Current | Range : 600A
Resolution : 0.1A Accuracy : 600A : ±(2%rdg±2dgt) |
Optional
Accessories: PROVA 15 (including plug wire) |
Range | 4A | 30A |
| Resolution | 1mA | 10mA | |||
| Accuracy | ±(2%rdg± 2dgt) |
±(2%rdg± 3dgt) |
|||
| Open Circuit Voltage | 5V max | ||||
| Manual and Auto Data Memory & Read | 999 data sets | ||||
| Auto Datalogging | micro SD CARD 4GB (maximum 99 blocks) | ||||
| Comparator | Setting : Resistance upper and lower limits and voltage threshold limit.
Memory : 99 sets of values |
||||
| Operating Environment | 0°C to 40°C (32°F to 104°F), 80%RH or less, non-condensing. | ||||
| Maximum Input Voltage | 60VDC | ||||
| Power Supply or AC Adapter | Six AA size 1.5V alkaline batteries | ||||
| Battery Life | 5.5 hours | ||||
| Dimensions/Weight | Approx. 198(L)x 94(W)x 49(H)mm /Approx. 530g | ||||
| Accessories | Large clip – type test lead with temperature sensor, Small clip-type test lead, Pin – type test lead, 3092CP DCA current adaptor, Zero adjustment board, Instruction manual, batteries, AC adaptor, USB cable, CD PC software, Carrying case. | ||||