The TES-1300/1303 are K-type thermocouple thermometers designed for single or dual-channel temperature measurement. They provide accurate readings across a wide range, support differential and dual-point display (TES-1303), and offer data output for recording.

  • Measuring Range: -50°C to 1300°C (-50°F to 1999°F) with dual-channel input on TES-1303.
  • Accuracy & Resolution: 0.3–0.75% of reading + offset, with 0.1°C/°F resolution for low ranges and 1°C/°F for higher ranges.
  • Data & Output Features: Maximum/Hold function, auxiliary output for data recording, T1/T2 dual-point display and differential measurement (TES-1303).
  • User-Friendly Design: Switchable °C/°F, compact size, battery-powered (9V), and flip-up stand for easy use.

Description

The TES-1300/1303 Thermometer is a compact, high-precision thermometer designed for K-type thermocouples, capable of measuring temperatures from -50°C to +1300°C (-50°F to +1999°F). It features selectable resolution (0.1°/1°) and user-selectable units (°C/°F), making it flexible for both industrial and laboratory applications. The device supports single-channel input (TES-1300) or dual-channel input with differential measurement (TES-1303), allowing simultaneous monitoring of two points with T1-T2 comparison.

Equipped with auxiliary outputs for data recording, a data hold function, and a flip-up stand, the thermometer is convenient for continuous measurements and analysis. Its durable design, powered by a 9V battery, provides long-lasting operation (100–200 hours), while clear LCD readings and room temperature compensation enhance accuracy and usability across varied working conditions.

 

Features

  • Switchable Type “K” Thermocouple Input Resolution 0.1°/ 1° with switching between °C and °F
  • Maximum Holding Power Hold Data Function
  • Aux output JACKS WITH ROOM TEMPERATURE COMPENSATION
  • T1 and T2 dual-point displays (1303)
  • Differential measurement T1 – T2(1303) Flip-up stand

Specifications

Measuring Rang -50°C ~ 1300°C, -50°F ~ 1999°F
Sensor K Type Thermocouple
Input Single Channel / Dual Channel
 

Resolution

-50°C ~ 199.9°C…… 0.1°C

-50℉ ~ 199.9°F…… 0.1°F

(Others 1°C/1°F)

 

 

 

Accuracy

-50°C ~ 199.9°C…0.3%rdg + 1°C

-50°F~ 199.9°F…0.3%rdg + 2°F

-50°C ~ 1000°C…0.5%rdg + 1°C

-50°F ~ 1999°F…0.5%rdg + 2°F 1000°C ~ 1300°C…0.75%rdg + 1°C

(apply to mainframe only at 23°C ± 5°C)

Auxilitary Outputs (for Data Recording) 1mV/°C (°F)…at 0.1°C/0.1°F range

0.1mV/°C (°F)…at 1°C/1°F range

 

Temperature Coefficient

Less that 0.1 times the applicable accuracy specification per °C (°F)
 

Input Protection

60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector
Sampling Rate 2.5 times/sec
 

Operating Conditions

0°C ~ 50°C (32°F ~ 122°F)

0 ~ 80% R.H.

Power Source One 9V battery (006P or IEC6F22)
Size/Weight 135mm(L)×72mm(W)×31mm(H) / 235g
Battery Life 200 hours (1300) / 100 hours (1303) (Alkaline Battery)
Accessories Battery, Instruction, Manual