Description
The Digital Insulation Tester is designed for accurate insulation resistance testing in industrial and electrical applications. It features a high-resolution LCD with 50-segment analog bargraph, making it easy to read at a glance. The tester supports auto-ranging for megaohm measurements, ensuring fast and precise readings up to 4000MΩ.
Equipped with over-range and low battery indicators, the device maintains user safety during tests. It generates a 200mA short-circuit continuity current and auto-discharges for safety after insulation tests. The tester can interface with PCs via RS-232, allowing users to log up to 16,000 measurements. Its robust CAT II 1000V / CAT III 600V rating ensures compliance with international safety standards (IEC 61557), making it suitable for use in industrial, commercial, and maintenance environments.
Specifications
GENERAL SPECIFICATIONS :
| Display |
80 x 50mm Big LCD penal with 50 segments analog display Max Reading 4000 |
| Over range Indication |
“OL” will be shown on the LCD penal when out of range measurement is made. |
| Low Battery Indication |
The will be shown when the battery need to be changed |
| Sampling Rate |
2.5 times/sec Digital Display 10 times/sec Bar Graph |
| Power Source |
Eight 1.5Volt AA size Battery |
| Operating Temperature and Humidity |
0°C to 40°C (32°F to 104°F ), below 80% RH |
| Storage Temperature |
-10°C to 60°C ( 14°F to 140°F ) |
| Dimension |
190(L)x140(W)x77(H)mm |
| Weight |
Approx. 900g (with battery) |
| Accessories |
Test leads, 8pcs battery, Carrying case, operation manual, CD software |
ELECTRICAL SPECIFICATIONS :
◊ OHMS & Continuity Beeper
| Range |
Resolution |
Accuracy |
Max. open Circuit Voltage |
Max. Short Circuit Current |
Overload Protection |
| 40Ω |
0.01Ω |
1%+30 |
12.8V |
>200mA |
220Vrms |
| Range |
Resolution |
Beeper Active |
Max. open Circuit Voltage |
Overload Protection |
| |
0.01Ω |
Resistance<4Ω |
12.8V |
220Vrms |
◊ AC Voltage (40Hz ~ 500Hz)
| Range |
Resolution |
Accuracy (above 1V) |
Input Impedance |
Overload Protection |
| 600V |
0.1V |
1.5%+3 |
4.5MΩ |
750Vrms |
◊ Meg OHMS (Auto Range)
| Range |
Resolution |
Accuracy |
Terminal Voltage |
| 4MΩ/40MΩ/400MΩ/ 4000MΩ/250V |
1K |
3%+5 (<2000M)
5%+5 (>2000M) |
250V+20%~-0% |
| 4MΩ/40MΩ/400MΩ/ 4000MΩ/500V |
500V+20%~-0% |
| 4MΩ/40MΩ/400MΩ/ 4000MΩ/1000V |
1000V+10%~-0% |
| Range |
Test Current |
Short circuit current |
| 4000MΩ/250V |
1mA |
250KΩ (load) |
≦1.5mA |
| 4000MΩ/500V |
500KΩ (load) |
| 4000MΩ/1000V |
1MΩ (load) |