The Precision Dual-Channel Multimeter is engineered for both laboratory and industrial applications where high accuracy is critical. It measures DC and AC voltage, current, and resistance with minimal deviation, providing fast, reliable readings. The device features single-channel and dual-channel operation, allowing simultaneous monitoring while accounting for supplemental accuracy adjustments. Overload protection ensures safe use across a wide voltage and current range.
Equipped with advanced circuitry and high-impedance input design, this multimeter ensures stable and repeatable measurements. It provides detailed readings in both standard units and PPM for dual-channel voltage differences (V1–V2). With easy-to-read resolutions, accurate ranges, and compliance with stringent specifications, it is ideal for precision testing of electrical components, research, quality control, and troubleshooting in complex systems.
Specifications
DC Voltage: (Input Impedance: 10M)
| Range |
Resolution |
Accuracy |
Overload Protection |
| 60.000mV |
0.001mV |
±0.2%±9dgts |
DC 1000V |
| 600.00mV |
0.01mV |
±0.1%±6dgts |
DC 1000V |
| 6.0000V |
0.0001V |
±0.1%±6dgts |
DC 1000V |
| 60.000V |
0.001V |
±0.1%±6dgts |
DC 1000V |
| 600.00V |
0.01V |
±0.1%±6dgts |
DC 1000V |
| 1000.0V |
0.1V |
±0.1%±6dgts |
DC 1000V |
AC Voltage:
| Range (ACV) |
Resolution |
Accuracy (50/60Hz) |
Accuracy
(45Hz – 1KHz) |
| 60.000mV |
0.001mV |
±0.2%±40dgts |
±0.6%±40dgts |
| 600.00mV |
0.01mV |
±0.2%±40dgts |
±0.6%±40dgts |
| 6.0000V |
0.0001V |
±0.2%±40dgts |
±0.6%±40dgts |
| 60.000V |
0.001V |
±0.2%±40dgts |
±0.6%±40dgts |
| 600.00V |
0.01V |
±0.2%±40dgts |
±1.5%±40dgts |
| 1000.0V
(0 – 400V) |
0.1V |
±0.2%±40dgts |
±4%±60dgts |
| 1000.0V
(400 – 1000V) |
0.1V |
±0.2%±40dgts |
(45Hz – 400Hz)
±4%±60dgts |
| Range (ACV) |
Accuracy (20Hz – 45Hz) |
Accuracy (1KHz – 10KHz)
|
| 60.000mV |
±1.6%±50dgts |
±4%±40dgts |
| 600.00mV |
±1.6%±50dgts |
±2%±40dgts |
| 6.0000V |
±1.6%±50dgts |
±2%±40dgts |
| 60.000V |
±1.6%±50dgts |
±2%±40dgts |
| 600.00V (0 – 400V) |
±1.6%±50dgts |
±5%±40dgts |
| 600.00V (400 – 600V) |
±1.6%±50dgts |
Not Specified |
| 1000.0V (0 – 400V) |
±1.6%±50dgts |
±4%±80dgts |
| 1000.0V (400 – 1000V) |
±1.6%±50dgts |
Not Specified |
DC Current
| Range |
Resolution |
Accuracy |
| 600.00uA |
0.01uA |
±0.4%±20dgts |
| 6000.0uA |
0.1uA |
±0.2%±20dgts |
| 60.000mA |
0.001mA |
±0.4%±20dgts |
| 600.00mA |
0.01mA |
±0.2%±20dgts |
| 1.0000A |
0.001A |
±0.2%±20dgts |
| 10.000A |
0.001A |
±0.6%±20dgts |
AC Current
| Range (ACA) |
Resolution |
Accuracy (50/60Hz) |
Accuracy
(45Hz – 1KHz) |
| 600.00uA |
0.01uA |
±0.6%±40dgts |
±0.8%±40dgts |
| 6000.0uA |
0.1uA |
±0.6%±40dgts |
±0.8%±40dgts |
| 60.000mA |
0.001mA |
±0.6%±40dgts |
±0.8%±40dgts |
| 600.00mA |
0.01mA |
±0.6%±40dgts |
±0.8%±40dgts |
| 1.0000A |
0.0001A |
±0.6%±40dgts |
±0.8%±40dgts |
| 10.000A |
0.001A |
±0.9%±40dgts |
±0.9%±40dgts |
| Range
(ACA) |
Accuracy
(20Hz – 45Hz) |
Accuracy
(1KHz – 10KHz) |
| 600.00uA |
±2%±20dgts |
±4%±20dgts |
| 6000.0uA |
±2%±20dgts |
±4%±20dgts |
| 60.00mA |
±2%±20dgts |
±0.9%±20dgts |
| 600.00mA |
±2%±20dgts |
±0.9%±20dgts |
| 1.0000A |
±2%±20dgts |
±2.5%±20dgts |
| 10.000A |
±3.9%±20dgts |
±2.5%±20dgts |
Supplement Dual Channels Specification (DC – 400Hz):
The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
|
ACV (Ch2) |
DCV (Ch2) |
ACA (Ch2) |
DCA (Ch2) |
| ACV
(CH1) |
±2%
±(V1 – V2)
200 PPM
(Ch1, Ch2) |
±0.9%
±(V1 – V2)
20 PPM
(Ch1, Ch2) |
±0.2uA/V(uA,Ch2)
±2uA/V(mA,Ch2)
±0.4mA/V(A,Ch2)
±4mV/A(mV,Ch1)
±9mV/A(V,Ch1) |
±0.5%
(Ch1,Ch2)
|
| DCV
(CH2) |
±0.9%
±(V1 – V2)
20PPM
(Ch1, Ch2) |
±0.5%
(Ch1,Ch2) |
±0.5%
(Ch1, Ch2) |
±0.5%
(Ch1, Ch2) |
The result of (V1 – V2) PPM is of volts.
V1: the voltage reading in volts of channel 1
V2: the voltage reading in volts of channel 2
PPM: Parts per million, Ch1: Channel 1, Ch2: Channel 2
Resistance: Ω
| Range |
Resolution |
Accuracy |
Overload Protection |
| 999.99 Ω |
0.01 Ω |
±0.25%±9dgts |
AC1000V |
| 9.9999KΩ |
0.0001KΩ |
±0.25%±6dgts |
AC1000V |
| 99.999KΩ |
0.001KΩ |
±0.25%±6dgts |
AC1000V |
| 999.9KΩ |
0.01KΩ |
±0.25%±6dgts |
AC1000V |
| 9.9999MΩ |
0.0001MΩ |
±0.3%±9dgts |
AC1000V |
| 40.000MΩ |
0.001MΩ |
±1.5%±9dgts |
AC1000V |