Phone

+603-5621 5786

Business Hour

08:30 - 17:30

Description

Specifications:

Wind Speed
Range: Heated 0-65 m/s & Unheated 0-75 m/s
Resolution: 0.01 m/s
Starting Threshold: 0.01 m/s
Accuracy: ±2% ± 0.1 m/s (30 m/s); ±3% (65m/s)
Response Time < 0.25 seconds
Wind Direction
Range: 0 to 360 degrees
Resolution: 0.1 degree
Starting Threshold: 0.01 m/s
Accuracy: ± 2 degrees
Response Time: < 0.25 seconds
Serial Output: RS232 or RS485
Formats: ASCII, ASCII polled, NMEA, RMYT SDI -12
Baud: 1200, 4800, 9600, 19200, 38400
Wind Units: m/s, knots, mph, kmph
Wind Format: Speed & Direction or U & V
Status Indicator: Standard with ASCII & NMEA
Analog Output
Range: 0-5000 mV or 4-20 mA
Analog Speed Scale: 0-100 m/s
Analog Direction Scale: 0-360 or 0-540 degrees
Output Update Rate: User Adjustable: 0.1 to 20 Hz
Power Requirement
Sensor: 10-30 VDC < 20 mA typical
Heater: 24 VDC, 2.5 A (Model 820458 Only)
Environmental
Operating Temperature: -40 to +60°C
Protection Class: IP65
Physical
Dimensions: 29 cm high x 11 cm wide
Weight: 0.4 kg (0.9 lb)
Shipping Weight: 1.6 kg (3.5 lb)