Hanna Instruments HI96802 Digital Refractometer for % Fructose by Weight Analysis

The HI96802 is a reliable, portable digital refractometer for food items that can measure the amount of fructose in aqueous solutions as a percentage of the solution’s total weight (%w/w). Results are reported by the HI96802 with an accuracy of 0.2%. The meter’s functioning is streamlined by having just two buttons: one for calibrating with distilled or deionized water and the other for taking measurements.

According to the ICUMSA Methods Book standard, all readings are automatically temperature-compensated and displayed with a 1.5 second response time. The stainless steel well and sealed flint glass prism are both simple to clean. Simply clean with a gentle towel to get ready for the subsequent sample.

 

Sample size as small as 2 metric drops (100 μl)

 

Sealed stainless steel well with high grade optical prism made of flint glass

 

Fast 1.5 second response time for temperature compensated readings

Description

The refractive index of a food sample is converted to percent fructose by weight using the HI96802 Digital Fructose Refractometer. The tables in the ICUMSA Methods Book (International Commission for Uniform Methods of Sugar Analysis) that show how the refractive index changes with temperature for a % by weight fructose solution provide the basis for this conversion.

Fruits, energy drinks, puddings, soy milk, juices, jam, marmalade, honey, soups, jellies, tofu, and sauces are all excellent candidates for analysis with the HI96802. The HI96802 is a simple-to-use device for determining the amount of sugar in food samples in a lab or out in the field.

  • Designed for food sugar analysis
  • Temperature Compensation algorithms based on fructose solution
  • 0 to 85% fructose by weight range with an accuracy of ± 0.2%

Making a Standard % Fructose Solution

To make a Fructose Solution, follow the procedure below:

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.
  • Tare the balance.
  • Weigh out X grams of high purity fructose (CAS #: 57-48-7) directly into a beaker
  • Add distilled or deionized water to the beaker so the total weight of the solution is 100g.
  • Note: Solutions above 65% may need to be vigorously stirred or shaken and heated in a water bath to roughly 40°C (104°F). Remove solution when fructose has dissolved and allow to cool before use.

Example to prepare as 25% fructose solution:

Fructose % (g/100g) Fructose (g) Water (g) Total (g)
25 25.000 75.000 100.000

 

Refractive Index

The refractive index of a sample is used by the HI96802 to take measurements. The refractive index gauges the behavior of light as it travels through the sample. Light will refract and reflect differently depending on the makeup of the sample. The refractive index of the sample can be examined by measuring this activity with a linear image sensor and utilized to ascertain its physical characteristics, such as concentration and density. The HI96802 enables measurement through the use of an LED light, prism, and lens in addition to a linear image sensor.
Depending on the component present, temperature changes will have an impact on a solution’s density. For reliable findings in digital refractometry, temperature adjustment must be used. The HI96802 has a built-in temperature sensor and is programmed with temperature adjustment algorithms for a % by weight fructose solution in line with the ICUMSA Methods Book.

 

Features at-a-glance:

One-point calibration

  • Calibrate with distilled or deionized water

Small sample size

  • Sample size can be as small as 2 metric drops (100 μl)

Automatic Temperature Compensation (ATC)

  • Samples automatically compensated for temperature variations

Quick, accurate results

  • Readings are displayed in approximately 1.5 seconds

Dual-level LCD

  • The dual-level LCD displays % Brix and temperature readings simultaneously
Stainless steel sample well

  • Easy to clean and corrosion-resistant

Battery indicators

  • Battery percent level remaining at startup and low battery indicator

Automatic shut-off

  • To conserve battery life the meter shuts off automatically after three minutes of non-use

IP65 water resistant protection

  • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.
More Information
SKU HI96802
Product Name Digital Refractometer for % Fructose by Weight Analysis – HI96802
Quote Required Yes
Sugar Content Range 0 to 85% mass (% w/w fructose)
Sugar Content Resolution 0.1% mass
Sugar Content Accuracy ±0.2% mass
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Automatic Shut-Off after three minutes of inactivity
Battery Type/Life 9V / approximately 5000 readings
Dimensions 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight 420 g (14.8 oz.)
Refractometer Light Source yellow LED
Minimum Sample Volume 100 μL (to cover prism totally)
Sample Cell stainless steel ring and flint glass prism
Measurement Time approximately 1.5 seconds
Ordering Information HI96802 is supplied with battery and instruction manual
Notes Enclosure Rating