Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES PROVA iCal Documenting Multifunction Calibrator and Arbitrary Function Generator

  • The unique mapping function let you calibrate temperature (300 °C) or voltage (220V) directly.
  • iCal is a multifunction calibrator and an arbitrary function generator.
  • Source: mA (4 to 20mA), V (0 to 15V, 0 to 70mV), Hz, sine wave, square wave, triangular wave, truncated sine wave, user programmable waveform, and temperature for 11 types of thermocouples.
  • Measure: current (mA), voltage (V, mV) and temperature (℃ or °F).
  • Programmable cold junction compensation allows users to fine tune temperature output and measurement.
  • Programmable 0% and 100% value for easy 25% step function.
  • Output error warning when output is shorted or open.
  • Short circuit protection for voltage output. Clear and easy user interface (numerical key pad, sliding switch and dot matrix LCM
  • with backlight).
  • Voltage, frequency, PWM duty-cycle (square wave and triangular wave), and offset are programmable in the Hz function.
  • Frequency range (0.3Hz to 20KHz) covers application of audio band (speaker, MP3, MD etc.)
  • DTMF (Dual Tone Multi-Frequency) can
  • perform professional testing for telephone line and audio product (MP3 or MD).
  • Auto-step and auto-ramp functions can quickly perform linear test.
  • PC can program calibrator through USB port.
  • Data logging with programmable sampling time (0~255 sec.) and memory of 4000 records.
  • Rechargeable lithium battery (1600mAH) with built-in charging circuit.
  • Calibration results (source & measure) can be saved in memory (2000 records).
  • Then users download them to a PC for documentation.
  • To distinguish calibration data at different locations, data can be saved under different file names.

Description

Electrical Specifications:

(23+/- 5, 10 minutes after turning on the power) mA (source) (Vopen > 15V)

Range Resolution Accuracy of Reading
-4mA to -0.005mA 1uA +/-0.03% +/- 5dgts
0.005mA to 4mA 1uA +/-0.03% +/- 5dgts
4mA to 20mA 1uA +/-0.03% +/-3dgts
20mA to 24mA 1uA +/-0.03% +/-5dgts

V (source) (maximum load 1mA, short circuit protection < 100mA)

Range Resolution Accuracy of Reading
-3V to -0.005V 0.001V +/-0.03% +/-5dgts
0.005V to 10V 0.001V +/-0.03% +/-5dgts
10V to 15V 0.001V +/-0.03% +/-5dgts

mA (measure)

Range Resolution Accuracy of Reading
-4mA to -0.005mA 1uA +/-0.03% +/- 5dgts
0.005mA to 4mA 1uA +/-0.03% +/- 5dgts
4mA to 20mA 1uA +/-0.03% +/-3dgts
20mA to 24mA 1uA +/-0.03% +/-5dgts

If reading of mA (measure) is less than 5 digits, it is displayed as 0.

V (measure)

Range Resolution Accuracy of Reading
-3V to -0.005V 0.001V +/-0.03% +/-5dgts
0.005V to 10V 0.001V +/-0.03% +/-5dgts
10V to 24V 0.001V +/-0.03% +/-5dgts

If reading of V (measure) is less than 5 digits, it is displayed as 0.

Frequency (source, 10 Vpp, 0V offset, square wave, duty cycle = 50%)

Range (Hz) Input Resolution Accuracy
0.3 to 99.999 0.1Hz 0.002Hz
10.00 to 999.99 0.1Hz 0.02Hz
1000.0 to 9999.9 0.1Hz 0.2Hz
10000 to 20000 1Hz 2Hz
Temperature, Thermocouples

(source and measure, 0.1C & 0.1F Resolution, Internal Cold Junction

Compensation, thermocouple accuracy not included, 3 minutes after plugging in thermocouples.)

 

°C °F
Range Accuracy Range Accuracy
K -200 to -150 2.0 -382 to -238 3.6
-150 to 0 1.2 -238 to 32 2.1
0 to 1000 0.8 32 to 1832 1.4
1000 to 1370 1.2 1832 to 2498 2.1
J -200 to -150 2.0 -382 to -238 3.6
-150 to 0 1.0 -238 to 32 1.8
0 to 1050 0.7 32 to 1922 1.2
E -200 to -150 1.5 -382 to -238 2.7
-150 to 0 0.9 -238 to 32 1.6
0 to 850 0.7 32 to 1562 1.2
T -200 to -150 1.5 -382 to -238 2.7
-150 to 0 1.2 -238 to 32 2.1
0 to 400 0.8 32 to 752 1.4
R 0 to 500 1.8 32 to 932

 

3.2
500 to 1760 1.5 932 to 3200 2.7
S 0 to 500 1.8 32 to 932 3.2
500 to 1760 1.5 932 to 3200 2.7
N -200 to 0 1.5 -328 to 32 2.7
0 to 1300 0.9 32 to 2372 1.6
L -200 to 0 0.9 -328 to 32 1.6
0 to 900 0.7 32 to 1652 1.2
U -200 to 0 1.1 -328 to 32 1.9
0 to 600 0.7 32 to 1112 1.2
B 600 to 800 2.2 1112 to 1472 3.9
800 to 1000 1.8 1472 to 1832 3.2
1000 to 1820 1.4 1832 to 3308 2.5
C 0 to 1800 1.0 32 to 3272 1.8
1800 to 2310 1.5 3272 to 4190 2.7
mV -10mV to 70mV 0.05mV -10mV to 70mV 0.05mV

 

Voltage Peak to Peak for Sine Wave

(Vpp, 0.3~20KHz, 50% duty cycle, sine wave, 0V offset)

Range (V) Resolution Accuracy of Reading
0.1 to 20V 0.001V 5% +/- 0.3V

 

Voltage Peak to Peak for Non-Sine Wave (Vpp, 0.3~20KHz, 0V offset)

Range (V) Resolution Accuracy of Reading
0.1 to 20V 0.001V 6% +/- 0.4V

 

Voltage Peak to Peak (Vpp, 0.3~20KHz, 50% duty cycle, square wave, 0V offset)

Range (V) Resolution Accuracy of Reading
1 to 20V 0.001V 6% +/- 0.4V

 

Voltage of Offset (Maximum Vpp < 20V)

Range Resolution Accuracy of Reading
-5V to 5V 0.001V 5% +/-0.5V +/-5%xVpp

 

Duty Cycle (%, square wave, 10 Vpp, 0.3~20KHz)

Range Resolution Rise Time of Vpp Fall Time of Vpp
0 to 100% 1% 10μS max, 5μS typical 15μS max, 7.5μS typical

DTMF (Hz)

Range (Hz) Resolution Accuracy of Reading
0.3 to 99.999 0.1Hz 0.002Hz
10.00 to 999.99 0.1Hz 0.02Hz
1000.0 to 9999.9 0.1Hz 0.2Hz
10000 to 20000 1Hz 2Hz

DTMF (%)

Range (%) Resolution Accuracy of Reading
0% ~ 100% 1% 5%

DTMF (Phase Angle)

Range (°) Resolution Accuracy of Reading
0 ~ 360 100μS+1°

DTMF (Vpp, F1=F2, <1 KHz, %1=%2, Phase1=Phase2)

Range Resolution Accuracy of Reading
5V ~ 20V 0.001V 10% +/-0.6V

DTMF (Offset, F1=F2,<1 KHz, %1=%2, Phase1=Phase2)

Range Resolution Accuracy of Reading
-5V ~ 5V 0.001V 10% +/-0.6V +/-5%xVpp

 

General Specifications:

 

DC 15V / 0.5A output
Dimension: 214.0(L) x 98.7(W) x 56.0(H) mm, 8.4″ (L) x 3.9″ (W) x

2.2″ (H)

Weight: 650g / 22.9oz (Batteries included)
Operation

Environment:

0°C ~ 50°C, 85% RH
Storage Environment: -20°C ~ 60°C, 75% RH
Accessories: Carrying case x 1, User manual x 1, AC adaptor x 1, USB cable x 1, Software CD x 1, Software manual x 1, K-type thermocouple (dual plugs) x 1,

Alligator clips x 2 (black and red), Test leads x 2 (black and red),

Rechargeable lithium battery (11.1V/ 1600mAh) x 1

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.