TES True RMS Multimeter TES-2900

True RMS Multimeter
  • Variable – frequency drive (VFD) V & Hz measurement
  • Lo – Z Voltage measurement to drain ghost voltages
  • Check 3 phase sequence
  • Voltage harmonic ratio measurement
  • Smart ohm for ground resistance measurement
  • Data hold & Auto hold mode
  • Max/Min/Avg record mode
  • Backlight LCD display
  • Relative value display
  • Frequency count. (Auto-Range)
  • Temperature type K, J measurment
  • Capacitance measurement
  • Data memory & read function

Description

SPECIFICATIONS:

Accuracies ±(…% of reading +…digits) at 23°C±5°C and below 80%RH

 

AC Voltage

AC conversions are ac-coupled and valid from 3% to 100% of range

Range Resolution Accuracy
45 – 65 Hz

 

15 – 200 Hz 200 – 440Hz 400 – 1kHz 1 – 5kHz 5 – 20kHz
999.9mV 0.1mV ±(0.7%+4)  

±(1.0 % + 4)

±(2%+4) ±(2%+20)

[1]

9.999V 0.001V
99.99V 0.01V  

 

±(0.7%+2)

±(2%+4)

[2]

Unspecified
999.9V 0.1V Unspecified
 

VFD

 

 

±(1.0%+4)

+1.0%+4

-0.6%-4

[3]

 

Unspecified

 

Unspecified

 

Unspecified

[1] Below 10% of range, add 12 counts

[2] Frequency range: 1 to 2.5kHz

[3] Specifications increases from -1% to -6% at 440Hz when filter is used

 

DC Voltage, Conductance, and Resistance

Function Range Resolution Accuracy
mV dc 999.9mV 0.1mV ±(0.1% + 1)
 

V dc

9.999V 0.001V  

±(0.05% + 1)

99.99V 0.01V
999.9V 0.1V
 

 

999.9Ω 0.1Ω ±(0.2% + 2) [2]
9.999kΩ 0.001kΩ  

±(0.2% + 1)

99.99kΩ 0.01kΩ
999.9kΩ 0.1kΩ
9.999MΩ 0.001MΩ ±(2% + 1)
50.00MΩ 0.01MΩ ±(5% + 1) [1]
nS 99.99nS 0.01nS ±(5% + 10) [1,2]

[1] Add 0.5% of reading when measuring above 30MΩ in the 100MΩ range, and 20 counts below 33nS in the 100nS range

[2] When using the rel function to compensate for offers. Smart Ω: ±(1% + 2)

 

Temperature

Thermocouple Type Range Accuracy
K -40 to 1372°C (-40 to 2502 °F)  

±1.0%±1°C(2°F)

J -40 to 1200°C (-40 to 2192 °F)

[1] Does not include error of the thermocouple probe

[2] Accuracy specification assumes ambient temperature stable to ±1°C. For ambient temperature changes of ±5°C, rated accuracy applies after 2 hours.

 

AC Current (45Hz to 10kHz)

Function Range Resolution Burden Voltage Accuracy
µA ac 999.9 µA 0.1 µA 100 µV/ µA  

 

±(1.0% + 2)

9999 µA 1 µA 100 µ µA/ µA
 

mA ac

99.9mA 0.1mA 3.6mV/mA
400.0mA 0.1mA 3.6mV/mA
A ac 9.999A 1mA 50V/A

AC conversions is true rms responding, and valid from 3% to 100% of range, except 400mA range.

(5% to 100% of range) and 10A range (15% to 100% or range).

 

Capacitance

Range Resolution Accuracy
10.00nF 0.01nF ±(2.0% + 2) [1]
100.0nF 0.1nF
1.000µF 0.001µF  

±(2.0% + 2)

10.00µF 0.01µF
100.0µF 0.1µF
9999µF 1µF
[1] With a film capacitor or better, using the rel mode to zero residual.

 

Diode

Range Resolution Accuracy
2V 0.001V ±(1.0% + 1)

 

3ϕ Phase Sequence Indication

Range Frequency Response Overload Protection
80V to 480V 50Hz/60Hz 1000V

 

Frequency Counter Sensitivity

Input Range Approximate Voltage Sensitivity (rms sine wave) [1]
5Hz to 100Hz 100Hz to 100kHz
999.9mV 50mV [VFD] 50mV
9.999V 500mV [VFD] 500mV
99.99V 5V [VFD] 5V
999.9V 50V [VFD] 50V
Input Range Approximate Current Sensitivity (rms sine wave)
5Hz to 100Hz 100Hz to 10kHz
999.9 µF 50 µF [VFD] 50 µF
9999 µF 500 µF 500 µF
99.99mA 5mA [VFD] 5mA
400.0mA 50mA 50mA
9.999A 1A [VFD] 1A
[1] Maximum input = 10 x range (1000V maximum, 2 x10^7 V-Hz product maximum)

[VFD]: Enabled Low Pass Filter

 

Hz Logic Level Frequency

Range Sensitivity
5Hz to 9999Hz 3.0Vp square wave

 