Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES AC 1000A Clamp Meter TES-3079M

TES-3079M
AC 1000A Clamp Meter
Product Features
  • 10 in 1 multifunction clamp meter
  • Voltage, Current, Power, Horse power, Reactive power, Apparent power, Phase angle, Frequency, Power factor, Phase sequence, Temperature, Resistance, Capacitance, Diode
  • Trms reading/Dual display/Auto power off

Description

 ELECTRICAL SPECIFICATIONS (23℃±5℃)

AC Current (50Hz to 400Hz) : Trms 

Range Resolution Accuracy Sensitivity Overload Protection
99.99A    10mA ±2% ±30dgts (50, 60Hz)

±4% ±30dgts (40~400Hz)

0.10A 1000A ac
999.9A   100mA 1.0A

 

ACA Inrush Current : 

Range Resolution Sensitivity Measurement Time Overload Protection
99.99A 0.01A >5A 100mS 1000A ac
999.9A 0.1A >50A

 

mA Trms : (AC+DC) (Burden Voltage : 5mV/µA) 

Range Resolution Accuracy Sensitivity Overload Protection
99.99mA    10nA ±1% ±30dgts 0.20µA 600V
999.9mA   100nA 2.0µA

 

AC Voltage (50Hz to 400Hz) : Trms 

Range Resolution Accuracy Sensitivity Overload Protection
999.9mV 0.1mV ±1% ±30dgts (50, 60Hz)

±2% ±30dgts (40~400Hz)

2.0mV 600V ac
9.999V 1mV 0.020V
99.99V 10mV 0.20V
600.0V   100mV 2V

 

DC Voltage 

Range Resolution Accuracy Sensitivity Overload Protection
999.9mV 0.1mV ±1.0% ±30dgts 2.0mV 600V
9.999V 1mV 0.020V
99.99V 10mV 0.20V
600.0V   100mV 2V

 

Resistance (Continuity<40Ω on the 999.9Ω range) : 

Range Resolution Accuracy Overload Protection
999.9Ω 100mΩ ±1% ±10dgts 600V
9.999KΩ 1Ω
99.99KΩ 10Ω
999.9KΩ 100Ω

 

MΩ: 

Range Resolution Accuracy Overload Protection
9.999MΩ 1KΩ ±5% ±10dgts 600V
99.99MΩ 10KΩ

 3∅ Phase sequence indication : 

Range Frequency Response Overload Protection
80V to 480V 50Hz / 60Hz 600V ac

  Capacitance : 

Range Resolution Accuracy Overload Protection
10.000μF 1nF ±1.5% ±5dgts 600V
100.00μF 10nF
1000.0μF 100nF
7000μF F ±2.5% ±15dgts

 Diode (Continuity<40mV) : 

Range Resolution Accuracy Overload Protection
2.000V 1mV ±2% ±1dgt 600V

 Temperature (K-Type ther mocouple) : 

Range Resolution Accuracy Overload Protection
-50ºC to 900ºC 0.1ºC ±0.2% ±1ºC 30V ac or 60V dc
-58ºF to 1000ºF 0.1ºF ±0.2% ±2ºF

 1f/3f TRUE Power (KW): (PF>0.5 or θ<60º ) 

Range Resolution Accuracy Overload Protection
99.99KW 10W ±5%rdg ±30dgts

(50, 60Hz)

600V ac / 1000A ac
600.0KW 100W

 

1∅/3∅ Horse Power (HP): (PF>0.5 or θ<60º ) 

Range Resolution Accuracy Overload Protection
99.99HP 0.01HP ±5%rdg ±30dgts

(50, 60Hz)

600V ac / 1000A ac
800.0HP 0.1HP

 

1∅/3∅Apparent Power : 

Range Resolution Accuracy Overload Protection
99.99KVA 10VA ±2.5%rdg ±30dgts 600V ac/

1000A ac

600.0KVA 100VA

 

1∅/3∅Phase Angle : (50Hz, 60Hz) 

Range Resolution Accuracy Sensitivity
-60° ~ 0° ~ +60° 0.1º ±6.0º ACV>100V, ACA>10A

 

Frequency : 

Range Resolution Accuracy Sensitivity
40Hz/1KHz 0.1Hz ±0.5%rdg ±2dgts ACV>1.2V, ACA>6A

 

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.