TES AFLEX-3005 Flexible Power Quality Tester

  • AC current measurement up to 3000A (True RMS): basic accuracy 1% of range
  • AC voltage measurement up to 600V (TrueRMS): basic accuracy 0.5% of range
  • AC watt measurement up to 9999KW: basic accuracy 1% of range
  • Power quality analysis for single and balanced 3-phase system
  • Measurement of balanced 3Φ power quality and phase sequence
  • Active (W, KW, HP), Reactive (VAR, KVAR), and Apparent (VA, KVA) power
  • Power factor (PF), Phase angle (Φ), and Energy (WH, KWH)
  • 1 to 50th order of harmonics at 2.0% basic accuracy
  • Total harmonic distortion (%THD-F) and Crest factor (CF)
  • Frequency of ACV or ACA: 45 ~ 65 Hz Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
  • Work with PC via USB interface Programmable CT ratio from 1 to 250 Max / Min / Data Hold functions
  • Auto power off function in 30 minutes Data logging memory size: 8000 records

Description

Electrical Specifications: (23±5)

AC Watt

(50 or 60 Hz, PF 0.5 to 1, CT=1, V>AC 5V, Current>AC 5A for A range)

 

Range

(5 to 3000A)

Resolution Accuracy of Readings
> 20 V and > 30A < 20V or < 30A
10.0 – 999.9 W 0.1W ±1% of range ±2% of  range
1.000 – 9.999 KW 0.001 KW ±1% of range ±2% of range
10.00 – 99.99 KW 0.01 KW ±1% of range ±2% of range
100.0 – 999.9 KW 0.1 KW ±1% of range ±2% of range
1000 – 9999 KW 1 KW ±1% of range ±2% of range

 

AC Apparent Power (VA, from 0.000VA to 9999 KVA)

 

 

Range

(5 to 3000A)

Resolution Accuracy of Readings
> 20 V and > 30A < 20V or < 30A
10.0 – 999.9 VA 0.1VA ±1% of range ±2% of range
1.000 – 9.999 KVA 0.001 KVA ±1% of range ±2% of range
10.00 – 99.99 KVA 0.01 KVA ±1% of range ±2% of range
100.0 – 999.9 KVA 0.1 KVA ±1% of range ±2% of range
1000 – 9999 KVA 1 KVA ±1% of range ±2% of range

 

AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR)

Range

(5 to 3000A)

 

Resolution

Accuracy of Readings
> 20 V and > 30A < 20V or < 30A
10.0 – 999.9 VAR 0.1VAR ±1% of range ±2% of range
1.000 – 9.999 KVAR 0.001 KVAR ±1% of range ±2% of range
10.00 – 99.99 KVAR 0.01 KVAR ±1% of range ±2% of range
100.0 – 999.9 KVAR 0.1 KVAR ±1% of range ±2% of range
1000 – 9999 KVAR 1 KVAR ±1% of range ±2% of range

 

Power Factor (PF)

Range Resolution Accuracy
> 20V and > 30A < 20V or < 30A
0.000 – 1.000 0.001 ± 0.04 ±0.1

 

AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4, CT=1)

Range Resolution Accuracy of Readings
5.0 – 300.0A 0.1A ±1% of range
300.0 – 999.9A 0.1A ±1% of range
1000 – 3000 A 1 A ±1% of range

 

AC Voltage (50/60 Hz, Auto Range, TRMS, C.F.<4, Overload Protection AC 800V)

Range Resolution Accuracy of Readings
4.0 V – 600.0 V 0.1 V ±0.5% ± 5dgts

 

Harmonics of AC Voltage in Percentage

Range Resolution Accuracy
1 – 20th 0.1% ±2%
21 – 50th 0.1% 4% of reading ± 20dgts

 

Harmonics of AC Voltage in Magnitude

Range Resolution Accuracy
1 – 20th 0.1V ±2% ± 0.5V
21 – 50th 0.1V 4% of reading ±0.5V

 

Harmonics of AC Current in Percentage

Range Resolution Accuracy
1 – 20th 0.1% ±2%
21 – 50th 0.1% 4% of reading ± 20dgts

 

Harmonics of AC Current in Magnitude (True RMS<300A)

Range (5 – 300A) Resolution Accuracy
1 – 20th 0.1A ±2% of reading ±0.4A
21 – 50th 0.1A ±4% of reading ±0.4A

 

Harmonics of AC Current in Magnitude (3000A>True RMS>300A)

Range Resolution Accuracy
1 – 20th 0.1A ±2% of reading ±40A
21 – 50th 0.1A ±4% of reading ±40A

 

Phase Angle (Φ, V > 20V, A > 30A)

Range Resolution Accuracy
-180° to 180° 0.1° ± 1°
0° to 360° 0.1° ± 1°

 

Total Harmonic Distortion

Range Resolution Accuracy
0.0 – 20% 0.1% ± 2%

 

 

20 – 100% 0.1% ± 6% of reading ± 1%
100 – 999.9 % 0.1% ± 10% of reading ± 1%

 

Peak Value of AC Voltage (RMS value > 10V) or AC Current (RMS value > 30A)

Range Sampling Time Accuracy of Reading
50 Hz 39 μs ± 5% ± 30 digits
60 Hz 33 μs ± 5% ± 30 digits

 

Crest Factor (C.F.) of ACV (RMS value > 10V) or ACA (RMS value > 30A)

Range Resolution Accuracy of Readings
1.00 – 99.99 0.01 ± 5% ± 30 digits

 

Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)

Range Resolution Accuracy
45 – 65 0.1 ± 0.2Hz

General Specifications:

Probe Length: 3005-24 24 in / 610 mm
Minimum Bending Diameter: 35mm
Connector Diameter: 23mm
Cable Diameter: 14mm
Cable Length from Probe to Box: 1700mm
Cable Length from Box to Output: 1700mm
Dimension (Box): 130mm(L) x 80mm(W)x 43mm(H) 5.1”(L) x 3.1”(W) x 1.7”(H)
Battery Type: two 1.5V SUM-3
Battery life: 200hrs @ 2000mAH.
Display: 4+4 digits LCD
Range Selection: Auto
Overload Indication: OL
Power Consumption: 10mA(approx.)
Low battery Indication:
Auto-Power-Off: 30 minutes after power-on
LCD Update Time: 2 times/sec.
No. Of Samples per Period 512 (voltage or current) 256 (power)
Data logging memory size: 8000 records
Data logging sampling time: 0~600 sec
Data logging period: 8000 x sampling time (0~600 sec.)
Operating Temperature: 5°C to 50°C
Operating Humidity: 15% to 85% RH
Altitude: up to 2000M
Storage Temperature: -20°C to 60°C
Storage Humidity: 15% to 85% RH
Weight: 430g (battery included)
Accessories: Test leads Carrying case x 1 Users manual x 1 Batteries 1.5V x 2 Software CD x 1