Phone

+603-5621 5786

Business Hour

08:30 - 17:30

TES Digital Multimeter TES-2712

TES-2712

DIGITAL MULTIMETER

Product Features

  • Manual range with unit display
  • Inductance measurement
  • Capacitance measurement
  • Frequency measurement Peak detectmeasurement

 

Description

Electrical Specifications :

Accuracies aqre + (…% of reading + …digits) at 23”C+ 5°C and below 80% RH. DC Voltage :

DC Voltage :

Range Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV  

 

0.5%+1

 

 

10M0

600Vrms
2V 1mV  

 

750Vpp

20V 10mV
200V

600V

100mV
1V 0.5%+2

 

AC Voltage : 50Hz – 500Hz

Range Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV  

 

1%+5

 

 

10M!

600Vrms
2V 1mV  

 

750Vpp

20V 10mV
200V

600V

100mV
1V 1.2%+5

 

DC Current :

Range Resolution Accuracy Burden

Voltage

Overload Protection
200uA 0.1uA  

 

1%+1

 

 

0.35V

 

 

0.5A/250V fast blow fuse & Diode

2mA 1uA
20mA

200mA

10uA
100uA
 

20A

 

10mA

 

1.2%+3

 

0.8V

20A/380V fast blow fuse 10A Continuity

20A for 30 sec. max.

 

AC Current : 50Hz 500Hz

Range              Resolution Accuracy Burden Voltage Overload Protection
200uA 0.1uA  

 

1.2%+3

 

 

0.35V

 

 

0.5A/250V fast blow fuse & Diode

2mA 1uA
20mA

200mA

10uA
100uA
 

20A

 

10mA

 

1.5%+3

 

0.8V

20A/380V fast blow fuse 10A Continuity

20A for 30 sec. max.

 

Resistance

Range Resolution Accuracy Open Circuit Voltage Overhead protection
200V 0.1CI 3.2V
2KCt 1CI
20KCt 100 0.8%+ 2  

0.5V

600Vrms
200KCI 100CI
2M0 1KCI
20MCt 10K0 1.5%+ 3

 

Diode Test

Range Resolution                   Accuracy Open Circuit Voltage Text Current Overload Protection
1mV                2%+ 2 3.2V 1.0mA 660Vrms

Audible Continuity
Range Resolution Continuity beeper Max Open Circuit

Voltage

Overload

Protection

0.1C 5200 3.2V 660Vrrns

 

 

Frequency ( Hz )( Test Range 10Hz – 10MHz Auto Range )

Range Resolution Accuracy Max. Open Circuit Voltage Overload Protection
2KHz 1Hz  

 

0.5%+2

 

 

1.5Vrms

 

 

600Vrms

20KHz 10Hz
200KHz

2000Hz

10MHz

100Hz
1KHz
10KHz 3Vrms

 

Inductance (The accuracy is based on when “Q” value is greater than 1)

Range Resolution Accuracy Test Frequency
20mH 10uH  

 

5% + 10

 

 

200Hz

200mH 100uH
2H

20H

1mH
10mH

 

Capacitance (F)

Range Resolution Accuracy Test Frequency
2000pF 1pF  

 

3% + 10

 

 

200Hz

200nF 100pF
2uF

20uF

1nF
10nF

 B: Peak Hold Measurement (Capture and retain elusive voltage or variant surge long enough for reading)

 

DC Voltage :

Range Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV  

 

1%+2

 

 

10MCI

600Vrms
2V 1mV  

 

750Vpp

20V 10mV
200V

600V

100mV
1V

 

AC Voltage : 50Hz – 500Hz

Range            Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV  

 

1.8%+7

 

 

10M0

600Vrms
2V 1mV  

 

750Vpp

20V 10mV
200V

600V

100mV
1V

DC Current :

Range               Resolution Accuracy Burden Voltage Overload Protection
200uA 0.1uA  

 

1.5%+2

 

 

0.35V

 

 

0.5A/250V fast blow fuse & Diode

2mA 1uA
20mA

200mA

10uA
100uA
 

20A

 

10mA

 

1.8%+2

 

 

0.8V

 

20A/380V fast blow fuse 10A Continuity

20A for 30 sec. max.

 

AC Current : 50Hz – 500Hz

Range               Resolution Accuracy Burden Voltage Overload Protection
200uA 0.1uA  

 

2%+5

 

 

0.35V

 

 

0.5A/250V fast blow fuse & Diode

2mA 1uA
20mA

200mA

10uA
100uA
 

 

20A

 

 

10mA

 

 

2.5%+8

 

 

0.8V

 

20A/380V fast blow fuse 10A Continuity

20A for 30 sec. max.

General Specifications:
  • Numerical Display: 3-1/2 digit liquid crystal display (LCD) maximum reading 1999 and Bargraph
  • Palarity: Automatic ” ” negative polarity
  • Overrange: ” ” appears on the
  • Sampling Rate: 5 readings per second.
  • Power: 9-Volt battery, NEDA1604, IEC6F22 or JIS006P.
  • Operating Storage Temperature and Humidity: 0°C to 40°C, below 80% RH/-10°C to 60°C, beIow70%
  • Dimensions & Weight: 180(L) x 82(W) x 38(H)mm / 365 g
  • Accessories: Test leads, Spare fuse (0.SA/250V), Battery, Operating

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.