Phone

+603-5621 5786

Business Hour

08:30 - 17:30

AutoMet 580 & 136 MultiMet Interface Module

Features:
AUTOMET 580
  • Ethernet, MODBUS, 12 analogue outputs, USB, RS-232C, and RS-485 are all capable of strong communication.
  • Averaging, maximum, minimum, delta, STD DEV, dewpoint, and other statistical computations.
  • For measurements of the global horizontal & plane of the array, matched pyranometer inputs.
  • For very precise and broad temperature readings, use the PT-100 platinum temperature inputs.
136 MULTIMET INTERFACE MODULE
  • 12 analogue outputs and 8 analogue inputs.
  • 3 MET or AIR sensors can be used as Met One digital sensor inputs.
  • logging data.
  • Different serial outputs
  • RTU MODBUS.
  • Sixteen-bit resolution
  • Fully Field Modifiable and Configurable.
  • Economical.

Description

136 MULTIMET INTERFACE MODULE Specifications:

PARAMETER SPECIFICATION
Analog Sensor Inputs 8 channel single ended 0 – 2.5 or 0 – 5 VDC user selectable, with 136 Multi- Met Interface Module Auto ID Sensor option

2 channel inputs for small signal solar radiation sensors 3 channel inputs for RTD platinum temperature sensors

Special Input 2 channel frequency counters (wind speed frequency selectable as low or high range or low AC millivolt

1 channel rain gauge channel (de-bounced switch closure with excitation resistor to 5 volts)

Digital Sensor Inputs Multiple Digital sensors, 8 channels max (Met One Instrument Sensors)
Voltage Outputs 12 voltage output channels 16 bits unipolar

5.000VDC full scale (selectable to 1.000 or 2.5 VDC full scale)

+/- 4 millivolts accuracy

Alarm Outputs 2 alarm channels with N.O. relay contacts (max power 24 VDC @ 20 mA)
Communication Ethernet serial port, 38400 baud fixed USB serial port shared with main port

Main RS-232 serial port, 1200-115200 baud, ASCII, N, 8, 1 Digital Sensor, RS-232, 9600 baud fixed

RS-485

Extra port, RS-232, 1200-115200 baud

Communication Protocol 7500 MetRecord Protocol for digital sensors and serial communications UIM serial report string

Modbus

Log Channels 16 logging channels (combination of digital, analog measurements, and calculated values)
Logging Data Capacity 1-minute data – 7.2 days 5-minute data -36 days 10-minute data – 72 days

15-minute data – 108 days 30-minute data – 216 days

1 hour – 433 days (1.2 years)

Power Requirements 15 VDC ± 20%

50 mA or less (display off) 125 mA (display on)

Power Source 120-240 VAC, 50-60 HZ to 15 VDC power supply (included) Solar panel array and battery (optional)

Battery and AC powered charger (optional)

Display Backlit LCD with auto time-out 40-character width

Eight lines

Keypad Four operation selection keys Four motion selection keys Four function selection keys
Environmental Operating temperature range: -20°C to +60°C (extended range available) Humidity: 0-100%, non-condensing

 

Physical Specifications

PARAMETER SPECIFICATION
Dimensions 15.5 in (high) x 13.5 in (wide) x 7.0 in (depth)
Weight 7.8 lbs (3.5kg)

 

AUTOMET 580 Specifications:

PARAMETER SPECIFICATION
Analog Sensor Inputs 8 channel single ended 0 – 2.5 or 0 – 5 VDC user selectable, with AutoMet Auto ID Sensor option

2 channel inputs for small signal solar radiation sensors 3 channel inputs for RTD platinum temperature sensors

Special Input 2 channel frequency counters (wind speed frequency selectable as low or high range or low AC millivolt

1 channel rain gauge channel (de-bounced switch closure with excitation resistor to 5 volts)

Digital Sensor Inputs Multiple Digital sensors, 8 channels max (Met One Instrument Sensors)
Voltage Outputs 12 voltage output channels 16 bits unipolar

5.000VDC full scale (selectable to 1.000 or 2.5 VDC full scale)

+/- 4 millivolts accuracy

Alarm Outputs 2 alarm channels with N.O. relay contacts (max power 24 VDC @ 20 mA)
Communication Ethernet serial port, 38400 baud fixed USB serial port shared with main port

Main RS-232 serial port, 1200-115200 baud, ASCII, N, 8, 1 Digital Sensor, RS-232, 9600 baud fixed

RS-485

Extra port, RS-232, 1200-115200 baud

Communication Protocol 7500 MetRecord Protocol for digital sensors and serial communications UIM serial report string

Modbus

Log Channels 16 logging channels (combination of digital, analog measurements, and calculated values)
Logging Data Capacity 1-minute data – 7.2 days 5-minute data -36 days 10-minute data – 72 days

15-minute data – 108 days 30-minute data – 216 days

1 hour – 433 days (1.2 years)

Power Requirements 15 VDC ± 20%

50 mA or less (display off) 125 mA (display on)

Power Source 120-240 VAC, 50-60 HZ to 15 VDC power supply (included) Solar panel array and battery (optional)

Battery and AC powered charger (optional)

Display Backlit LCD with auto time-out 40-character width

Eight lines

Keypad Four operation selection keys Four motion selection keys Four function selection keys
Environmental Operating temperature range: -20°C to +60°C (extended range available) Humidity: 0-100%, non-condensing

 

Physical Specifications

PARAMETER SPECIFICATION
Dimensions 15.5 in (high) x 13.5 in (wide) x 7.0 in (depth)
Weight 7.8 lbs (3.5kg)

Ready to Transform Your Business? Contact Us Today

Categories

Request a Quote or Further Information

Please fill in the request form below and one of our engineers will contact you to discuss your system requirements and if we can help, our typical response time is within 1 – 3 working day.