TES-3600 3P4W POWER ANALYZER

TES-3600 3P4W POWER ANALYZER

 

FEATURES
  • 10 Display Easy – to – View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (512KB Memory, 20,000 sets)
  • Programmable Trigger – Points and Start / Stop Time.
  • RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy – to – use Push – Button Operation.
  • Light Weight, Portable Design. 

 

SPECIFICATIONS

Voltage Measurement (V)

 

Ranges

Method

Accuracy

Input impedance

999.9V

True RMS

± 0.5%rdg ± 10dgts (>30V)

2M Ω

 

Current Measurement (A)

 

Ranges

Method

Accuracy

250A ? 500A ? 1000A

True RMS

± 0.5%rdg ± 10dgts+clamp on sensor specifications

 

Active Power Measurement (KW)

 

Ranges

Accuracy

Effect of power factor

600.0KW

± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

 

Reactive Power Measurement (KVAR)

 

Ranges

Accuracy

Effect of power factor

600.0KVAR

± 0.5%rdg ± 10dgts+clamp on sensor specifications

± 0.1%rdg

 

Apparent Power Measurement (KVA)

 

Ranges

Accuracy

600.0KVA

± 0.5%rdg ± 10dgts+clamp on sensor specifications

 

Power Integration Measurement

 

Power Integration

Resolution

Accuracy

0.0KWh to 9999MWh

0.1KWh

± 0.5%rdg ± 10dgts+clamp on sensor specifications

0.0Kvarh to 9999Mvarh

0.1Kvarh

0.0KVAh to 9999MVAh

0.1KVAh

 

Power Factor Measurement

 

Ranges

Accuracy

Polarity display

-1.000(lead) to 0.000 to + 1.000 (lag)

± 1dgt for each calculation from measured values

When the current lags the voltage unsigned ; when the current leads the voltage : "-".

 

Frequency Measurement

 

Ranges

Measurement source

Accuracy

40Hz to 100Hz

Voltage U1

± 0.5%rdg ± 1dgt

 

General Specifications

 

Size

235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)

Operating Temperature and Humidity

0 ? to 50 ? (32 ? to 122 ? ) R.H. < 80% non-condensing

Storage Temperature and Humidity

- 10 ? to 60 ? (14 ? to 140 ? ) R.H. < 70% non-condensing

Accessories

Instruction manual , Software CD Rom / Optical RS-232 interface , Deluxe carrying case , Battery (“AA” 1.5V ′ 8pcs ) , AC adaptor (110V -> 12V ; 220V -> 12V) , 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm) , 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)